background image

2

3

4

5

7

8

9

10

11

6

12

13

Instruction Manual

 

HCT-P01 

Series

Created: July 2017 (1st Edition)

Safety precautions (Important)

About this product

Confirmation of Package Contents

DANGER

Sections with this heading have contents that “have a high 
possibility of death or suffering from serious injuries.”

WARNING

Sections with this heading have contents that “are assumed to 
have a possibility of death or suffering from serious injuries.” 

CAUTION

Sections with this heading have contents that “have a possibility of suffering from 
injuries or assumed to have a possibility of property damage only occurring.”

This symbol refers to things which must not be done, i.e. are “prohibited”.

This symbol refers to things which must be done, i.e. are “mandatory”.

DANGER

Keep this product away from children and do not let them play or ride 

on the main unit or the gel pad.

It will cause accidents or injuries.

Do not use this product for any other purpose than exercising.

It will cause accidents or problems.

WARNING

Do not disassemble, repair or modify.

It will cause a fire or electric shock.

WARNING

CAUTION

Do not forcibly pull, bend, or place any heavy objects on top of the 

cable.

It can cause cable damage, disconnection, and lead to a fire or electric 

shock.

Do not insert any metallic objects into the USB connector slot.

It will cause a fire or heat generation.

Do not touch the USB connector slot with any parts of your body (e.g. 

hand or finger).

It will cause an electric shock, fault or malfunction.

CAUTION

Attaching the gel pad

Preparation

CAUTION: 

Make sure there are no missing parts before use. The product is packed with 
the greatest care, but if you still find any missing or damaged parts, contact the 
distributor you purchased the product from.

Items sold separately

The following items are sold separately.

Connection terminal (gel pad side)

Protective film

Gel pad

Main unit x 1

Accessories

Instruction manual 
(this manual) × 1 
Stretch manual × 1
Storage sheet × 1
Storage bag × 1
Dedicated USB cable × 1

Core pad x 1 
(consumable)

CAUTION: 

Do not use this product on any of the following body parts:

 • around the heart (e.g. chest), or upper body parts higher than the neck 

(e.g. head, face)

 • mucous membrane (e.g. wound, eye, mouth and genitals)

 • body parts that have undergone plastic surgery

 • body parts with metal, plastic or silicone implanted

 • backbone, spine  • body parts with tattoos

 • abdomen region during menstruation

 • body parts with necklace, watch or body piercing

Main unit

USB A connector

USB micro B connector

Make sure to turn off the power when you are connecting/disconnect-

ing the gel pad, putting on / re-positioning / peeling off the gel pad or 

changing the gel pad.

Check for damage, chipping or deformation of the gel pad surface 

before use.

If there is any, it will cause accidents, problems and malfunctions.

CAUTION

Do not submerge the main unit in water or any liquid, or let it become 

wet.

It will cause heat generation, bursting or a fire.

Do not store this product in a place where children can reach it. 

It might cause an accident. If a child swallows the main unit, consult 

a doctor immediately.

If any failures occur, stop using it immediately and turn it off. Contact 

the distributor or our information center.

When disposing, follow the instruction from your local municipal 

government. Do not disassemble when disposing.

Thank you for purchasing Eclear Lean. This manual details the operation method 
and precautions for the safe handling of the product. Please read this manual 
before use. After reading, keep this manual in a safe location for future reference.

This product is intended for one person use only. Do not use this 

product with more than one person.

It will cause accidents or electric shock.

If you feel any strong stimuli, rash, redness, itch or any abnormalities on 

your skin during use, stop using it immediately and consult a doctor.

It will cause accidents or health problems.

Do not use the enclosed USB cable for any other purposes than 

charging the main unit. The enclosed USB cable cannot be used for 

any other purposes such as for communication or charging other 

devices.

Do not use this product while you are exercising vigorously.
Moisture in sweat causes skin inflammation or the gel pad to lose 
adhesive strength.

CAUTION: 

Use the designated gel pad only.

Do not charge it using a transformer such as a travel converter.

It will cause a fire or heat generation.

Do not charge it inside a car using a cigar socket.

It will cause a fire or electric shock.

If you are charging it with a commercial charger of AC power supply, 

read its instruction manual thoroughly and follow the safety instructions.

Charge at least once in three months. 

After it is completely discharged, charging might be impossible.

When charging, insert the dedicated USB cable all the way.

If it is not inserted completely when charging, it might cause a fire or 

electric shock.

Do not touch the dedicated USB cable or the gel pad with wet hands.

It will cause an electric shock, failure or accidents.

Do not use the product if the dedicated USB cable is damaged, or 

the USB connector slot is loose.

It will cause a fire or electric shock.

Never use this product along with the following medical equipment:

 • Pacemakers and other implanted electric equipment

 • Heart-lung machines and other life-supporting medical electronic equipment

 • Electrocardiographs and other wearable medical electronic equipment

This product may open such equipment to malfunctions and may lead to 

serious consequences for your health.

WARNING

The following people must not use this product:

 • People with blood cots in their veins or arteries.

 • People whose doctors have prohibited them from exercising.

 • People who are pregnant, or have the possibility of being pregnant.

 • People who have been taking steroid type hormone drugs for a long 

period of time, or have a dysfunctional liver and are suffering from 

capillary dilatation

Do not attach the gel pad over any metallic items such as a 
necklace or a body piercing.

CAUTION: 

Do not use or store this product in the following locations:

 • Places with direct sunlight

 • Places with high temperature (e.g. near heaters)

 • Places with high humidity (e.g. bathroom)

 • Near water

 • Places with a lot of dust

 • Places with a lot of vibration

It will cause fire, electric shock or malfunctions.

Do not use while sleeping.

It will cause accidents or injuries.

Do not use right before driving or during driving.

t will cause accidents or problems.

Do not leave the gel pad on your skin for a long period of time

It will cause skin inflammation.

Do not use the gel pad when it is wet.

It will cause an electric shock.

Do not use more than 30 minutes on a single location.

It will cause accidents or health problems.

Please make sure the main unit and the gel pad are connected correctly 

and securely before use.

Do not use it on more than two locations at the same time.

It will cause accidents or health problems.

Check that each operation button functions correctly before use.

[0 to 24%]

[25 to 49%]

[50 to 74%]

LED

The pattern of LED changes depending on the remaining amount of 
battery.

[75 to 99%]

[Fully charged]

Eclear Lean

Read the following precautions thoroughly to prevent property damage or 
harm to you or other people.

The degree of the possible damage or risk you may cause if you misuse this 
product against these precautions are described in the following categories:

Do not use this product in the following cases.

 • When sudden pain is felt around the padding area

 • When drinking alcohol or smoking   • When severely fatigued

 • When sleeping or taking a bath

If you are seeing a doctor, or have the following conditions, be sure to 

consult your doctor before using.

 • People receiving treatment from a physician, or people who feel a 

particular abnormality in their body

 • People who have malignant tumors (cancer)

 • People who have an abnormality in their heart or cerebral nerve

 • People with a body temperature of 38ºC or higher (during fever)

*Example 1: 

Acute onset of symptoms (e.g. fatigue, chills and blood pressure fluctuation)

*Example 2: When feeling weak

 • People with infectious diseases

 • People with tactile perception disorder, or skin disorders

 • People with acute (painful) conditions such as a fractured spine, strained 

or pulled muscles

 • People that need to remain rested • People taking medication

 • People with blood pressure abnormality • People who are physically 

handicapped

 • People who cannot control the product on their own

 • People with perceptual disorder due to serious peripheral circulation 

disorder (e.g. diabetic)

 • People with a low body temperature • People with circulatory disorders

 • People who are allergic to gel pads • People with epilepsy (seizure)

It will cause accidents or health problems.

When you are using it for the first time or using it after not using it for a 

long period of time, please check that it operates correctly according to 

this instruction manual.

Accessories

Instruction manual 
(this manual) × 1 
Stretch manual × 1
Storage sheet × 1
Storage bag × 1
Dedicated USB cable × 1

Main unit x 2

Core pad x 1 
(consumable)

Twin pad x 2
(consumable)

Twin pad x 2
(consumable)

Accessories

Instruction manual × 1 
Storage sheet × 1

Core pad x 1 
(consumable)

Accessories

Instruction manual × 1 
Storage sheet × 1

Gel pad

Dedicated USB cable

Use the AC adapter for USB 5V output.

Do not use transformers such as travel converters since they might 
cause a fire or generate heat.

The main unit cannot be operated while charging.
The mobile battery might not be usable for charging.
The operable time will gradually decrease as you repeat charging. If 

the operation time becomes extremely short, the battery has expired 
but it is not replaceable.

Replacing gel pad

Handling the gel pad

Do not touch the attachment surface of the gel pad. 
When it loses its adhesiveness, see “Maintenance of 
gel pad” (page 19).
Do not bend the gel pad.

Charging

1

Connecting gel pad to main unit

2

Removing the protective film

1

Attaching the gel pad

2

Hold the grip on the protective film of the gel pad and peel it off.

Attach the gel pad to the desired body parts.

Starter Set

Twin pad (x 2)

Core pad (x 1)

Full set

* After the first use, peel it off from the storage film to use it.

Make sure the gel pad is firmly attached to your skin.
* If the gel pad is detached from your skin, the main unit is 

turned off automatically.

Plug the USB micro [B] connector of the dedicated USB cable into 
the USB connector slot of the main unit.

Plug the USB [A] connector of the included USB cable into the USB 
port of the PC or the AC adapter for charging, to supply the power.
It makes a long beep when charging is 
completed.

Take out the gel pad of the bag when using it for the first time. 

(Do not remove the protective film on the gel pad yet.)

Turn off the main unit and make sure that the LED light is turned off.

Push in the connecting terminal until it clicks to connect the main 
unit and the gel pad.

Remove the main unit from the gel pad.

Take out the gel pad from the bag.

 (Do not remove the protective film on the gel pad yet.)

Make sure that the main unit is turned off and the LED light is 
off.
Push in the connecting terminal of the gel pad until it clicks to 
connect the main unit and the gel pad.

If you are using it for the first time or after a long storage period, or the battery 
becomes low during use, charge it fully up to maximum.

What is EMS?

EMS is a product that aims to produce an exercising effect by moving muscles 
mechanically through stimulation with electricity.

What is deep layer frequency?

The deep layer frequency is a high frequency in the range of 2,000 to 5,000Hz. 
The higher the frequency is, the more the parts of the body where the fat is 
thick can be stimulated, and the core muscles of the body that are normally 
hard to move can be moved.

What is relaxation frequency?

The relaxation frequency is a low frequency in the range of 20 to 30Hz. By 
relaxing the muscles contracted by the deep layer frequency, you can train for 
long hours without exhausting your muscles.

Stretching

By using this product while muscles are stretched, you can train hard-to-train 
tendons and improve flexibility.

Recommended operating time

Up to 30 minutes per day for one location. Do not use this product for long 
hours since it might be harmful to your health.
In this product, an integrated timer turns off the power automatically every 
fifteen minutes after training starts.

Off

Flashing

Continuously lit

A - flashing

B - flashing,

A - continuously lit

C - flashing, 

A and B - continuously lit

Front side

Back side

Power button
(switch mode button)

D - flashing, 

A, B and C - continuously lit

A, B, C and D are 

all continuously lit

Charging time: Approx. 2.5 hours

HCT-P01PN1/HCT-P01BU1

Model number: HCT-P01G1

HCT-P01PN2/HCT-P01BU2

USB connector slot

PC

AC adapter 
for charging

Dedicated USB cable

micro B connector

It can be charged with a smartphone 
charging service (e.g. at hotels).

A Connector

Convex
“Strong” button

USB connector slot (for charging)

LED light

Concave
“Weak” button

Connection terminal (main unit side)

Model number: HCT-P01G2

Do not 

disassemble

No wet hands

For use in Japan only

This user's guide is based on the Pharmaceuticals and Medical Devices Law of Japan. A customer 
who purchases outside Japan should refer to the localized manuals in the country of purchase.

www.elecom.co.jp/global/download-list/manual/

Reviews: