Eldom Invest NHC-H52M-1S Technical Description Download Page 1

TECHNICAL DESCRIPTION

MANUAL FOR OPERATION AND POWER CONNECTION

of

ELECTRONIC THERMOSTAT
NHC-H52M-1S / NHC-H52M-2

for control of utility storage water heaters with electric heater/s to 3 kW, 230 V~, single phase

connection, designed for wall mounting

WARNING! Read carefully this manual before using the device!

The present instruction is an integral part of the general installation and operation

instruction attached to your water heater unit. All of the general instruction requirements

concerning the water heater installation and connection to the water supply and electricity

networks are absolutely in force. It is compulsory to follow the requirements listed in the

general instruction other sections.

This manual explains the features and usage of the electronic control unit, which replaces

the traditional thermostat and LED switch of the ordinary water heaters.

NHC-H52M / v220322

Confirm (Enter) / Information

▼/ Menu

▲/ Temperature setting

On-Off/ Back

Summary of Contents for NHC-H52M-1S

Page 1: ...ation and operation instruction attached to your water heater unit All of the general instruction requirements concerning the water heater installation and connection to the water supply and electrici...

Page 2: ...e listed in Table 2 Table 1 Models and features of the electronic units NHC H52M 1S NHC H52M 2 Thermostat control of the utility storage water electric heater heaters Control of the utility storage wa...

Page 3: ...eater Each interval can be set in any day of the week to switch on and to what temperature water can be heated Control of the solar collector circulation pump power depending on the temperature differ...

Page 4: ...tional protective conductor that never should be interrupted and or connected on the layout from the electric panel to the tank Otherwise the appliance shall not be correctly earthed and it shall redu...

Page 5: ...unit will not work and it is very possible to damage it and increase the risk of electric shock It is necessary to secure the power cord to the power circuit of the water heater and the power cord fr...

Page 6: ...wires in water heaters designed for wall mounting with one heat exchanger Fig 1 and with two heat exchangers Fig 2 The power cord phase conductor connects to the thermal cut out terminal labeled A1 or...

Page 7: ...Fig 2 Single phase connection of water heaters with two heat exchangers NHC H52M 2 3 DISPLAYS SETTINGS MENUS 3 1 Main display graphics and indications Fig 3 7...

Page 8: ...do not make any changes for a longer period between 20 seconds and 5 minutes depending on the settings menu you will automatically exit the selected menu without saving any changes made The only excep...

Page 9: ...protection against overheating of the solar collector by automatically switching to Holiday mode to discharge the stored energy 3 5 2 On All authorized heat sources shall be switched on see menu Heati...

Page 10: ...line but in column Off on the same line When this pump works the circulating pump on the image of the boiler on the display will rotate To protect the water tank from overheating the circulation pump...

Page 11: ...h off There is one more operation mode for the boiler pump set from the menu Heating Installation row Boiler Pump Mode CH Priority When this mode is activated in the menu Pumps control shall be used t...

Page 12: ...erature and it will switch on if the temperature of the lower thermo sensor t1 drops by 5 degrees less than the temperature set in Temp The timer allows exclusion of certain days of the week during wh...

Page 13: ...temperature that can be used for any household needs but at the same time if there is a strong sun it can take as well its heat 3 10 Pumps control Temperature settings for switching on and off the pum...

Page 14: ...accumulated heat in the water tank when you activate Holiday mode the temperature will be reduced to the value set in this field Use boiler pump NHC H52M 2 When this field is checked the discharge of...

Page 15: ...rature settings ATTENTION When for long periods you do not use hot water and the sun is strong enough do not disconnect the water heater from the apartment electricity panel This can damage the standi...

Page 16: ...y collected in the water heater during the day Holiday mode Solar anti frost Switched on mode for protecting the solar collector against freezing Freezing protection of the boiler Switched on mode for...

Page 17: ...d date to when the thermostat is working before you interrupted power supply Power supply on Time and date when the power supply is restored These messages will be registered only if the system clock...

Page 18: ...creen is the date concerning the information displayed while at the bottom is provided a summary for the day 4 5 Information By pressing the button Enter after the state Statistics by the hours shall...

Page 19: ...thermostat shall continuously monitor the temperature as the water in the water tank and the solar collector If necessary the protection mode shall be switched on for Anti freezing protection of the...

Page 20: ...late a new heat in order to discharge the solar collector The pump will operate until the temperature in the tank falls below the temperature set in Solar protection line Tank min temp This mode is in...