2015 eldoLED. All rights reserved. v1.3
More documentation and eldoLED’s terms and conditions are available at www.eldoled.com.
Pay attention when connecting the LED groups:
polarity reversal results in no light output and often damages the LEDs
Wiring diagram POWERdrive 561/S, 561/A (PW0561S1, PW0561A1)
WARNING: Risk of electrical shock. May result in serious injury or death. Disconnect power before servicing or installing.
CAUTION: The device may only be connected and installed by a qualified electrician. All applicable regulations, legislation and build-
ing codes must be observed. Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs.
LED outputs
R(ed) represents channel 1, G(reen) represents channel 2, B(lue) rep-
resents channel 3, and W(hite) represents channel 4. The default
group colour allocation can be changed using the TOOLbox pro and
freely available FluxTool application.
Maximum wiring distance at full load (from LED driver to LED load):
LEDcode/NTC
The LEDcode/NTC interface allows connection of a 47k
Ω
NTC therm-
istor for closed loop thermal control. The NTC throttle temperature is
programmable through the freely available FluxTool software (see
“Configuring your driver over DMX in”).
DMX in/DMX out
Connect the network cable’s DMX+, DMX- and DMX shielding wires
to the corresponding pin or wire on the LED driver.
For LED drivers that feature the WH0081S1 wiring harness, the wire
colors on the harness and corresponding colors in a CAT 5 cable are
listed in the following table.
The WH0081S1 wiring harness can be ordered from eldoLED.
Alternatively, if you wish to use a proprietary solution, the following
molex parts should be used: 1x wire-to-board housing 87439-0800
and 8x crimp terminal 87421-0000.
Configuring your driver over DMX in
Download the FluxTool software from your eldoLED driver’s product
web page and connect a TOOLbox pro to DMX in to configure your
driver. You can configure:
• various DMX parameters
• dimming curve
• minimum dimming level
• NTC throttle temperature
• LED drive current per output, from 200mA-1,050mA in 1mA steps
120-277V AC
The driver has been designed for use with universal mains voltage in-
put (120-277V AC, 50/60Hz), and for use with DC input (120-250V, as
used in emergency lighting).
AWG value
20
19
18
17
16
Distance (m)
14
18
22
28
36
Distance (ft)
46
59
72
92
118
Please observe voltage drop over long cable lengths.
Longer cable lengths increase EMI susceptibility.
For POWERdrive 561/A it is recommended to use shielded
multi-core wires between LED driver and LED engine. Prop-
erly connect shield to ground on both sides.
Wiring harness
CAT5 cable
DMX out shield
black
brown
DMX out -
black/blue
orange
DMX out +
black/white
orange/white
DMX in shield
black
brown
DMX in -
blue
orange
DMX in +
white
orange/white
120-277 VAC
L
N
4 LED outputs
4 control channels
2
1
9 mm
0.35 inch
Solid or stranded copper wires only.
0.5-1.5 mm
2
AWG 20-16
LED output 1
LED output 2
LED output 3
LED output 4
LEDcode/NTC
DMX out
DMX in
shield
-
+
shield
-
+
-
+