MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
EKB3
Please, refer to illuminated zone indicators ranging from 1 through 12 on the keypad. The
flashing indicator SYSTEM stands for violated high-numbered zones (Z13-Z44). For more
details on violated high-numbered zone indication, please refer to
29. INDICATION OF SYS-
TEM FAULTS.
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
View violated tampers
SMS
The system will automatically send an SMS text message, containing a violated tamper name,
to user phone number.
EKB2
Menu path:
OK
→
VIOLATED TAMPERS
→
OK
→
TAMPER 1... 44
EKB3
The illuminated indicator SYSTEM stands for system fault presence including violated tam-
per. For more details on violated tamper indication, please refer to
29. INDICATION OF SYS-
TEM FAULTS.
For more details on how to disable/enable SMS text messages and phone calls to the listed user phone number in case of alarm, please refer
to
17.1. Enabling and Disabling Alarm Notifications
ATTENTION:
Phone calls to the listed user phone number in case of alarm are disabled by force when MS mode is enabled (see 30. MONI-
TORING STATION).
NOTE:
If one or more zones/tampers are violated during the alarm, the system will attempt to send as many SMS text message and dial the
user phone number as many times as the zone/tamper was violated. The capacity of the queue is 24 events maximum.
NOTE:
If the system sent the SMS text message and/or dialled the user phone number after disarming the system, it means that the SMS
text message and/or phone call was queued up in the memory before the system was disarmed
17.1. Enabling and Disabling Alarm Notifications
By, default the system will ring the listed user phone numbers in case of alarm. To disable/enable this feature, please refer to the following
configuration methods.
Disable call in case of
alarm
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETTINGS
→
OK
→
CALL/SMS
SETTINGS
→
OK
→
CALL IN CASE ALARM
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 30 and parameter status value:
30 1#
Example:
301#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable call in
case of alarm
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETTINGS
→
OK
→
CALL/SMS
SETTINGS
→
OK
→
CALL IN CASE ALARM
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 30 and parameter status value:
30 0#
Example:
300#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
By, default the system will send SMS text message to the listed user phone numbers in case of alarm. To disable/enable this feature, please
refer to the following configuration methods.
Disable SMS text
message in case of
alarm
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
ALARM EVENT
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 25, event number and parameter status value:
25 03 0 #
Example:
25010#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable SMS text
message in case of
alarm
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
ALARM EVENT
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 25, event number and parameter status value:
25 01 1 #
Example:
25011#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
By default, the system sends SMS text message to the first available user in case of alarm. If the system did not receive the SMS delivery
report during 45 seconds, it will attempt to send the SMS text message to the next listed user phone number. To ignore the SMS delivery
report and allow/disallow the system to send the SMS text message to every listed user phone number, please refer to the following con-
figuration methods
Enable SMS text
message to all listed
user phone numbers in
case of alarm
SMS
SMS text message content:
ssss_SMSALL:ON
Value:
ssss
– 4-digit SMS password
Example:
1111_SMSALL:ON
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETTINGS
→
OK
→
CALL/SMS
SETTINGS
→
OK
→
SEND ALARM SMS ALL
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.