MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
Set Delay, ms atrribute
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable/disable Delay
becomes Instant in
Stay mode attribute
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Disable Chime
attribute
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
CHIME
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 32 and parameter status value:
32 0 #
Example:
320#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable Chime attribute
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
CHIME
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 32 and parameter status value:
32 1 #
Example:
321#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Set Alarm count to
bypass attribute for
individual zone
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
14.7. Bypassing and Activating Zones
NOTE for EKB3:
The Configuration mode must remain deactivated before bypassing a violated zone or activating a bypassed zone.
Zone bypassing allows the user to deactivate a violated zone and arm the system without restoring the zone. If a bypassed zone is violated
or restored during exit/entry delay, or when then system is armed, it will be ignored. When a zone is bypassed, EKB3 keypad indi cator
BYPS
will light ON and EKB2 keypad will display
BYP
message in the home screen view.
Bypass individual
violated zone
EKB2
Menu path:
OK
→
BYPASS
→
OK
→
BYPASS LIST 1... 3
→
OK
→
Z1-zone-name... Z44-zone-name
→
OK
→
BYPASS
→
OK K
Value:
zone-name
- up to 24 characters zone name.
EKB3
Press the [BYPS] key, enter zone number and user code:
BYPS nn uuuu #
Value:
nn
– zone number, range – [01... 44];
uuuu
– 4-digit user code.
Example:
BYPS091111#
Bypass all violated
zones
EKB2
Menu path:
OK
→
BYPASS
→
OK
→
BYP VIOLATED ZONES
→
OK
The zone will stay bypassed until the system is disarmed. Once the system is disarmed, the corresponding zone state will be indicated on
the keypads (see
31.1.1. EKB2 – LCD Keypad
and 3
1.1.2. EKB3 – LED Keypad
) and Info SMS text message (see
26. SYSTEM INFORMA-
TION. INFO SMS)
. Alternatively, the user can activate the bypassed zone by the following configuration methods.
Activate bypassed
zone
EKB2
Menu path:
OK
→
BYPASS
→
OK
→
BYPASS LIST 1...3
→
OK
→
Z1-zone-name... Z44-zone-name
→
OK
→
UNBYPASS
→
OK
Value:
zone-name
- up to 24 characters zone name.
EKB3
Press the [BYPS[ key, enter zone number and user code:
BYPS nn uuuu #
Value:
nn
– zone number, range – [01... 44];
uuuu
– 4-digit user code.
Example:
BYPS251111#
NOTE:
Zones can only be bypassed and activated when the system is not armed.
14.8. Zone Names
Each zone has a name that can be customized by the user. Typically, the name specifies a device type connected to a determined zone
terminal, for
Example:
Kitchen doors opened. The zone names are used in SMS text messages that are sent to the user during alarm. the
By default, the zone names are:
Z1 – Zone1, Z2 – Zone2, Z3 – Zone3, Z4 – Zone4 etc.
Set zone name
SMS
SMS text message content:
ssss_Znn:zone-name
Value:
ssss
– 4-digit SMS password;
nn
– zone number, range – [1... 44];
zone-name
– up to
24 characters zone name.
Example:
1111_Z3:Door sensor triggered
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
View zone names
SMS
SMS text message content:
ssss_STATUS
Value:
ssss
– 4-digit SMS password.
Example:
1111_STATUS
EKB2
Menu path:
On-board zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ONBOARD
ZONES
→
OK
→
ZONE 1... 12
→
OK
→
NAME
Wireless zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
WIRELESS
ZONES
→
OK
→
WLESS ZONE 1... 16
→
OK
→
NAME
Keypad zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
KEYPAD ZONES
→
OK
→
KEYPAD 1... 4 ZONE
→
OK
→
NAME
EPGM1 zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
EPGM1 ZONES
→
OK
→
EPGM1 ZONE 1... 16
→
OK
→
NAME
Value:
aaaa
– 4-digit administrator password.
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
ATTENTION:
Colon, semi-colon characters, parameter names and/or values, such as PSW, STATUS, ON, OFF etc. are NOT allowed in zone
names
NOTE:
Multiple zone names can be set by a single SMS text message,
Example:
1111_Z1:Kitchen doors opened;Z3:Movement in base-
ment;Z4:Bedroom window opened