Enter parameter 53, zone number and zone type number:
53 nn 1 #
– Interior Follower
53 nn 2 #
– Instant
53 nn 3 #
–24-Hour
53 nn 4 #
– Delay
53 nn 5 #
– Fire
53 nn 6 #
– Panic/Silent
Value:
nn
– zone number, range – [01... 44]
Example:
53125#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
NOTE:
The system will NOT activate siren/bell and keypad buzzer only when Panic/Silent zone type is violated.
14.6. Zone Attributes
• Stay
– If this attribute is enabled, the zone, regardless of type, will not cause an alarm if violated when the system is Stay armed. For
more details on arming the system in the Stay mode, please refer to
15. STAY MODE
.
• Force
– This attribute determines whether the system can be armed or not while a zone is violated. If a zone with the Force attribute
enabled is left violated until the exit delay expires, it will be ignored. Once the system is armed and the zone is restored, the violation
will not be ignored and the zone will operate according to the determined type. For more details on zone types, please refer to
14.5.
Zone Type Definitions
.
• Delay, ms
– This attribute determines the zone sensitivity level by delay time (by default – 800 milliseconds). If a zone is left triggered
until the delay time expires, the zone is considered violated.
• Delay becomes Instant in Stay mode
– This attribute determines whether or not any Delay type zone will operate as Instant type
zone when the system is armed in the Stay mode. When the system is fully armed, the Delay type zone will operate normally. For more
details on Delay and Instant zone types, please refer to
14.5. Zone Type Definitions
.
• Chime
– This feature is used to emit 3 short beeps from the keypad buzzer and display icon on EKB2 keypad screen whenever any
Delay type zone is violated. Typically, the feature is used for designated exit/entry doors to indicate the opening of the doors.
• Alarm count to bypass
– This attribute determines a number of times the zone can be violated until it is automatically bypassed.
For more details on zone bypassing and how to activate a bypassed zone, please refer to
14.7. Bypassing and Activating Zones.
Enable Stay attribute
for individual zone
EKB2
Menu path:
On-board zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ONBOARD
ZONES
→
OK
→
ZONE 1... 12
→
OK
→
STAY
→
OK
→
ENABLE
→
OK
Wireless zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
WIRELESS
ZONES
→
OK
→
WLESS ZONE 1... 16
→
OK
→
STAY
→
OK
→
ENABLE
→
OK
Keypad zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
KEYPAD
ZONES
→
OK
→
KEYPAD 1... 4 ZONE
→
OK
→
STAY
→
OK
→
ENABLE
→
OK
EPGM1 zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
EPGM1 ZONES
→
OK
→
EPGM1 ZONE 1... 16
→
OK
→
STAY
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 56, zone number and parameter status value:
56 nn 1 #
Value:
nn
– zone number, range – [01... 44].
Example:
56041#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Disable Stay attribute
for individual zone
EKB2
Menu path:
On-board zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ONBOARD
ZONES
→
OK
→
ZONE 1... 12
→
OK
→
STAY
→
OK
→
DISABLE
→
OK
Wireless zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
WIRELESS
ZONES
→
OK
→
WLESS ZONE 1... 16
→
OK
→
STAY
→
OK
→
DISABLE
→
OK
Keypad zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
KEYPAD
ZONES
→
OK
→
KEYPAD 1... 4 ZONE
→
OK
→
STAY
→
OK
→
DISABLE
→
OK
EPGM1 zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
EPGM1
ZONES
→
OK
→
EPGM1 ZONE 1... 16
→
OK
→
STAY
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 56, zone number and parameter status value:
56 nn 0 #
Value:
nn
– zone number, range – [01... 44].
Example:
56190#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable Force attribute
for individual zone
EKB2
Menu path:
On-board zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ONBOARD
ZONES
→
OK
→
ZONE 1... 12
→
OK
→
FORCE
→
OK
→
ENABLE
→
OK
Wireless zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
WIRELESS
ZONES
→
OK
→
WLESS ZONE 1... 16
→
OK
→
FORCE
→
OK
→
ENABLE
→
OK
Keypad zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
KEYPAD ZONES
→
OK
→
KEYPAD 1... 4 ZONE
→
OK
→
FORCE
→
OK
→
ENABLE
→
OK
EPGM1 zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
EPGM1 ZONES
→
OK
→
EPGM1 ZONE 1... 16
→
OK
→
FORCE
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 82, zone number and parameter status value:
82 nn 1 #
Value:
nn
– zone number, range – [01... 44].
Example:
82061#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Disable Force
attribute for
individual zone
EKB2
Menu path:
On-board zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ONBOARD
ZONES
→
OK
→
ZONE 1... 12
→
OK
→
FORCE
→
OK
→
DISABLE
→
OK
Wireless zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
WIRELESS
ZONES
→
OK
→
WLESS ZONE 1... 16
→
OK
→
FORCE
→
OK
→
DISABLE
→
OK
Keypad zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
KEYPAD
ZONES
→
OK
→
KEYPAD 1... 4 ZONE
→
OK
→
FORCE
→
OK
→
DISABLE
→
OK
EPGM1 zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
EPGM1 ZONES
→
OK
→
EPGM1 ZONE 1... 16
→
OK
→
STAY
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 82, zone number and parameter status value:
82 nn 0 #
Value:
nn
– zone number, range – [01... 44].
Example:
82110#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.