MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
Disable arm/disarm
notification for all
listed user phone
numbers
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETTINGS
→
OK
→
CALL/SMS
SETTINGS
→
OK
→
SEND ARM/DARM ALL
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 22 and parameter status value:
22 0 #
Example:
220#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
13. EXIT AND ENTRY DELAY
When arming, the system initiates the exit delay countdown (by default – 15 seconds) intended for the user to leave the secured area. The
exit delay is indicated by short beeps emitted by EKB2/EKB3 keypad buzzer and buzzer, connected to the alarm system. in addition, when
arming by EKB2 keypad,
icon will be displayed next to the countdown timer on keypad screen during exit delay.
• in a non-partitioned system,
icon will be displayed next to the countdown timer on EKB2 keypad screen during exit delay.
• in a partitioned system, EKB2 keypad will display
ARMING part-name
message on the screen for 3 seconds and switch to partition
selection menu during exit delay.
Exit delay is provided when arming the system by the following methods:
• EKB2/EKB3 keypad and user code.
• iButton key.
• EWK1/EWK2 wireless keyfob.
• Arm/Disarm by Zone.
To arm the system without exit delay, use one of the following system arming methods:
• Free of charge phone call.
• SMS text message.
• EGR100 middle-ware.
Set exit delay
SMS
SMS text message content:
ssss_EXITDELAY:ext
Value:
ssss
– 4-digit SMS password;
ext
– exit delay duration, range – [0... 600] seconds.
Example:
1111_EXITDELAY:20
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETTINGS
→
OK
→
EXIT DELAY
→
OK
→
ext
→
OK
Value:
aaaa
– 4-digit administrator password;,
ext
– exit delay duration, range – [0... 600]
seconds.
EKB3
Enter parameter 72 and exit delay duration:
72 ext #
Value:
ext
– exit delay duration, range – [0... 600] seconds.
Example:
72259#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
NOTE:
Alternatively, you can set exit delay value to 0 in order to arm the system without exit delay by any available method.
Once the exit delay has expired, the system initiates the entry delay countdown (by default – 15 seconds) if a Delay type zone is violated.
The countdown is indicated by short beeps emitted by keypad buzzer and by steady beep emitted by system’s buzzer. The indication is in-
tended to advise the user that the system should be disarmed. Once the user presses/touches any key on the keypad during this delay, the
buzzer of the keypad will be silenced. If the system is disarmed before the entry delay expires, no alarm will be caused.