3. INSTALLATION
• The system can be installed in a metal or non-flammable cabinet only. For a convenient installation, ME1 metal cabinet is highly recom-
mended. The metal cabinet must always be grounded as well as ESIM264 system’s PCB by connecting one of the COM terminals to the
PE contact of the metal cabinet.
• For the connection of 230V transformer, use 3x0.75 mm
2
(3x0.03in
2
) 1 thread double isolated cable. 230V power supply cables must
not be grouped with low voltage cable group.
• For the connection of auxiliary and BELL outputs, use 2x0.75 mm
2
(2x0.03in
2
) 1 thread unshielded cable of up to 100m (328.08ft)
length.
• For the connection of zone/PGM output connectors, use 0.50 mm
2
(0.02in
2
) 1 thread unshielded cable of up to 100m (328.08ft) length.
System Installation in ME1 Metal Cabinet
1. ME1 metal cabinet components
Tamper switch
to AC main power line
to AC/DC terminals
of ESIM264 system
Phase
PE
Null
blue
brown
Fuse 1A
Transformer
(Primary voltage: 230V AC,
Secondary voltage: 17V 2,35A)
14
2. Insert the plastic standoffs into the appropriate mounting points and fix the board of ESIM264 on the holders as indicated below.
mounting points
15
7
16
3. If EPGM1 module is to be installed, please install it in the first place and ESIM264 alarm system afterwards. EPGM1 must be mounted on
the shorter plastic standoffs, while ESIM264 – on the longer ones. The mounting points of EPGM1 module are indicated below.
mounting
points*
17
* The standard ME1 metal cabinet does NOT contain the mounting points intended for EPGM1 module mounting, therefore it will be nec-
essary to drill out the mounting points by yourself.