I02-118 User manual & maintenance guide
Version 04
(translation of the original manual)
of TLM 1000
Page
10
sur 25
4.8
Heavy positioning unit
Disassembly of the heavy positioning unit:
Unscrew the fixing screws that fasten the
positioning unit on the rails.
Take off the positioning unit from the
transfer system.
Unscrew the fixing screw fastening the
plate.
Remove the plate to allow access to the
drawer.
Every 1000 hours:
Lubrication of the drawer (inside and outside)
Use the recommended grease (grease Gulf Crown EP2).
Plate fixing screw