![ELBRO ST-SK1 Installation Manual Download Page 8](http://html1.mh-extra.com/html/elbro/st-sk1/st-sk1_installation-manual_2376901008.webp)
15
14
Zone setup of accessories
Every detector can be assigned to 4 different categories of zones: Home Zone, Delay Zone, Normal
Zone and 24-H Zone. To assign a detector to a zone, follow the instructions on page 8 of this
manual (the zone will be assigned at the time of connection of the accessory).
Normal zone
When the system is armed, if a sensor is triggered, the siren rings out. When the system is disarmed,
sensors do not trigger an alarm.
24h zone
Regardless the system is armed or disarmed, sensors assigned to the 24h zone can trigger an alarm.
It is recommended to assign smoke detectors, gas detectors and outdoor beam sensors to the 24-H
zone.
Delay zone
If you want to set up the entry and exit delay functions, corresponding sensors must be assigned to
the Delay zone. Once the delay time has been set up, the sensors will not trigger the alarm during
the delay set. Refer to the instructions “Entry and Exit Delay” on page 10 of this manual. It is
recommended to assign the Door / Window Contact to the Delay zone.
Home zone
When the system is armed in Home Mode, the sensors assigned to the Home zone do not trigger an
alarm. It is recommend to assign motion dectors to the Home zone so that you can have your system
armed in Home Mode when you are home and move inside your home without triggering any alarm.
Control by phone call
This feature is available only after having enabled it from the control panel, as explained on page
Method 1
When an alarm has been triggered, the control panel dials the stored phone numbers. When you
pick up the phone, follow the voice instructions to control the panel from distance (refer to the
instructions in the table below).
Method 2
1. Dial the telephone number of your control panel (either the number of the SIM card in your
control panel or the number of the landline to which your panel is connected). After getting through,
the voice instructions will guide you to enter your access code.
2. Enter your user code, followed by ”
#
”.
3. A voice gives you the options you can select.
4. Select the operations to control the panel (see instructions in the table below).
Note
The call will end automatically if you do not send any command within 30 seconds.
Table of commands for control by phone call
Command
Function
Comment
Press
“1“
Arms the system
Press
“0“
- Disarms the system and turns the
siren off
- Stops monitoring without hanging up
- Stops the phone call function without
hanging up
Press
“3“
Phone call with control panel
Press
"
*
"
- Starts audio monitoring mode (not
limited in time)
- Stops the built-in siren and the wire-
less siren (if connected to the control
panel)
-
Press
“6“
Turns all sirens off
-
Press
“9“
- Turns the built-in siren on (whether
the siren ringing settings is ON or
OFF)
- Turns the wireless siren on (if con-
nected to the control panel)
-
Press
“#“
- Turns all sirens off
- Exits control by phone call
- Stops call recycles
-
Note
In GSM mode, the audio monitoring is not limited in time.