SIXPAR 100IP™
user manual
EL
A
TI
O
N
|
SI
X
PA
R 1
00
IP
™
us
e
r m
a
n
ual
Page 1: ...SIXPAR 100IP user manual E L A TI ON SIXPAR 100IP user manual ...
Page 2: ...ve companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigg...
Page 3: ...T E N T S General Information 4 Warranty 7 Safety Instructions 8 General Guidelines 9 Fixture Overview 10 Fixture Installation 11 Understanding DMX 13 Fixture Menu 16 DMX Channel Functions And Values 19 Cleaning and Maintenance 22 Technical Specifications 23 Optional Accessories 25 ...
Page 4: ...nst particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and high pressure water jets from any direction 5 M A R I N E C O A S T A L E N V I R O N M E N T I N S T A L L A T I O N S Please note althoug...
Page 5: ...the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Male Edison to IP Female Power Cable 6 6 ft 2m Male 3pin XLR to IP Female DMX Input Cable 3 3 ft 1m Female 3pin XLR to IP Male DMX Output Cable 3 3 ft 1m Manual Warranty Card CUSTOMER SUPPORT Elation Professional provides a customer support line to provide set up help and to...
Page 6: ...pping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused and returned at customer s expense You may obtain a R A number by contacting customer support at 323 582 3322 I M P O R T A N T N O T I C E There are no user serviceable parts inside this unit Do not...
Page 7: ...aser by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Elation Professional will replace defective parts at its expense and will absorb all expen...
Page 8: ...K For proper operation follow the Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Any modifications will void the original manufactures warranty and increase the risk of damage and or personal injury Never look d...
Page 9: ...mable materials from the surface 1 6 feet 0 5m DO NOT attempt installation and or operation without knowledge how to do so DO NOT allow operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years to come DO NOT shake fixture avoid b...
Page 10: ...w w w e l a t i o n l i g h t i n g c o m 10 SIXPAR 100IP User Manual ver 1 F I X T U R E O V E R V I E W 1 MODE Button 2 UP Button 3 DOWN Button 4 ENTER Button 5 Power IN 6 DMX IN 7 DMX Out 8 Power OUT ...
Page 11: ...this temperature Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 95 lbs 43 kg Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing Ensure ALL connections and end caps ar...
Page 12: ...ating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully operational in the specific mounting positions as illustrated below S A F E T Y C A B L E Always use a Safety Cable whenever ...
Page 13: ...G To ensure proper DMX data transmission always use the SIXPAR series IP rated DMX cables listed in the OPTIONAL ACCESSORIES section at the end of this manual When using several DMX fixtures try to use the shortest cable path possible Never split a DMX line with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixtu...
Page 14: ...it or Y your DMX connections Address 1 Address 13 Address 25 DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs The use of a terminator may avoid erratic behavior in your DMX line A terminator is a 120 ohm 1 4 watt resistor that is connected between pins 2 and 3 of a male XLR connector DATA and DATA This fixture is inserted in the fema...
Page 15: ...gs of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the SIXPAR 100IP when in the 12 Channel Mode you ...
Page 16: ...the different function menus Once you reach a desired menu press the ENTER button to select that menu The variable field that can be adjusted within the selected menu will begin to flash Using the UP or DOWN buttons adjust the field until the desired value is displayed For example the CHANNEL CH menu variable field can be set to 06 07 08 or 12 Pressing the ENTER button once will confirm your selec...
Page 17: ... 07 08 12 DMX Channel Mode DMX MODE ADDR 001 512 DMX Address Setting SLAVE MODE SALVE MODE Set Fixture A Slave Unit Display ON ON LCD Display Always ON OFF LCD Display OFF after 30 seconds OFF1 LCD Display OFF After 30 Seconds and LOCKED Internal Programs 1 MANUAL Manual Color Adjustment R00 99 Adjust RED Brightness 00 99 G00 99 Adjust GREEN Brightness 00 99 B00 99 Adjust BLUE Brightness 00 99 W00...
Page 18: ... h t i n g c o m 18 SIXPAR 100IP User Manual ver 1 DIMMING CURVES The DimCurve menu allows you to select one of the following preset dimming curves Standard Stage TV Architec or Theatre See diagram below for more details Dimmer ...
Page 19: ... FUNCTION 6 CH 7 CH 8 CH 12 CH 1 1 1 1 RED 0 255 Red 0 100 2 2 2 2 GREEN 0 255 Green 0 100 3 3 3 3 BLUE 0 255 Blue 0 100 4 4 4 4 WHITE 0 255 White 0 100 5 5 5 5 AMBER 0 255 Amber 0 100 6 6 6 6 U V 0 255 U V 0 100 7 7 7 MASTER DIMMER 0 255 Dimmer 0 100 8 8 STROBE 0 31 LED OFF NO STROBE 32 95 Strobe Effect SLOW to FAST 96 127 LED ON NO STROBE 128 159 Strobe Pulse Effect In Sequences SLOW to FAST 160...
Page 20: ...BLUE 36 39 RED WHITE 40 43 RED AMBER 44 47 RED UV 48 51 GREEN BLUE 52 55 GREEN WHITE 56 59 GREEN AMBER 60 63 GREEN UV 64 67 BLUE WHITE 68 71 BLUE AMBER 72 75 BLUE UV 76 79 WHITE AMBER 80 83 WHITE UV 84 87 AMBER UV 88 91 RED GREEN BLUE 92 95 RED GREEN WHITE 96 99 RED GREEN AMBER 100 103 RED GREEN UV 104 107 RED BLUE WHITE 108 111 RED BLUE AMBER 112 115 RED BLUE UV 116 119 RED WHITE AMBER 120 123 RE...
Page 21: ... AMBER 196 199 RED BLUE WHITE UV 200 203 RED BLUE AMBER UV 204 207 RED WHITE AMBER UV 208 211 GREEN BLUE WHITE AMBER 212 215 GREEN BLUE WHITE UV 216 219 GREEN BLUE AMBER UV 220 223 GREEN WHITE AMBER UV 224 227 BLUE WHITE AMBER UV 228 231 RED GREEN BLUE WHITE AMBER 232 235 RED GREEN BLUE WHITE UV 236 239 RED GREEN BLUE AMBER UV 240 243 RED GREEN WHITE AMBER UV 244 247 RED BLUE WHITE AMBER UV 248 25...
Page 22: ...an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every 3 months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tig...
Page 23: ...ing 0 100 5 Variable Dimming Curve Modes CONTROL CONNECTIONS 4 DMX Channel Modes 6 7 8 12 4 Button Touch Control Panel LCD Menu Display IP DMX and Power In Out SIZE WEIGHT Length 10 1 257mm Width 6 2 158mm Vertical Height 9 6 243mm Weight 9 5 lbs 4 3 kg ELECTRICAL THERMAL AC 110 250V 50 60Hz 89W Max Power Consumption Power Linking 12pcs 110V 25pcs 240V 5 F to 113 F 15 C to 45 C APPROVALS RATINGS C...
Page 24: ... t i n g c o m 24 SIXPAR 100IP User Manual ver 1 PHOTOMETRIC DATA DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice ...
Page 25: ...t 3m IP Data Link Cable SIXPAR 3MPLC 9 8 ft 3m IP Power Link Cable SIXPAR 5MDLC SPECIAL ORDER ITEM 16 4 ft 5m IP Data Link Cable SIXPAR 5MPLC SPECIAL ORDER ITEM 16 4 ft 5m IP Power Link Cable SIXPAR 10MDLC SPECIAL ORDER ITEM 32 8 ft 10m IP Data Link Cable SIXPAR 10MPLC SPECIAL ORDER ITEM 32 8 ft 10m IP Power Link Cable SIXPAR 20MDLC SPECIAL ORDER ITEM 65 6 ft 20m IP Data Link Cable SIXPAR 20MPLC S...
Page 26: ......