DMX-512 control connection

 

Connect the provided DMX XLR cable to the female 3-pin XLR output of your controller and 

the other side to the male 3-pin XLR input of the moving head (Please refer to the diagram 

below.). You can chain multiple moving heads together through serial linking. The cable 

needed should be two conductor, shielded cable with XLR input and output connectors. 

Always be sure daisy chain your in and out data connections, never split or “Y” your DMX 

connections unless you are using an approved DMX splitter such as the Elation Opto Branch 

4™ or DMX Branch/4™.   

 

 

 

Please note: to ensure maximal stability, when the input voltage is 100~120V, only 8 

devices may be connected together in this manner! From the 9th devices, please connect to 

power supply to get power for the second link; when the input voltage is 220~240V, only 15 

devices may be connected together in this manner! From the 16th devi ces, please connect 

to power supply to get power for the second link 

 

DMX-512 connection with DMX terminator 

When longer runs of cable are used, you may need to use a terminator on the last fixture to 

avoid erratic behavior. A terminator is a 120 ohm 1/4 watt resistor that is connected between 

pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the 

female XLR connector of the last fixture in your daisy chain to terminate the line. Using a 

cable terminator (Elation part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

 

Summary of Contents for ELAR DW BRICK

Page 1: ...Rev 01 06 2011 Version 1 3 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 www elationlighting com...

Page 2: ...uidelines 7 5 Fixture Overview 8 6 Mounting and Installation 10 7 Understanding DMX 12 a DMX Connections 12 b DMX Terminator 13 c 3 Pin to 5 Pin Conversion 14 d Understanding DMX Addressing 14 8 Displ...

Page 3: ...ate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dea...

Page 4: ...e your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside...

Page 5: ...Operating the ELAR DW BRICK without suited safety aids such as safety cables or clamps can increase the risk of damage and or personal injury 5 Installation should only be performed by qualified and c...

Page 6: ...r cord of this luminaire is damaged it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard 16 Please be aware that damages c...

Page 7: ...d Female XLR Data Connectors Preprogrammed colored macros Strobe effect with a maximum flash rate of 18fps DMX controlled operation or stand alone operation with Master Slave function Individual contr...

Page 8: ...cation please be sure that the fixture will not be exposed to extreme heat moisture or dust The minimum distance between the fixture and a wall or flat surface should be at least 5 meter about 1 5ft A...

Page 9: ...embly Cool white warm white LED assembly 3 watt LEDS 2 Bracket Locking Knob This knob is used to secure the bracket in place after angle adjustments have been made 3 LED Housing This part include all...

Page 10: ...t lock connector When jumping from fixture to fixture be sure to only use Elation IP rated power connectors to maintain the IP rating 7 Power Output Jack Use this jack to jump power to another ELAR DW...

Page 11: ...yourself Improper installation can result in bodily injury Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Mounting Th...

Page 12: ...mp or be used in cluster allow multiple units to rigged together see the illustration below Regardless of the mounting option you choose please refer to the safety guidelines in this manual to avoid d...

Page 13: ...below Be sure to only use properly rated DMX cables for DMX operation and not standrd audio cables If you are constructing your own cables be sure to use two conductor shielded digital cable rated at...

Page 14: ...maximal stability when the input voltage is 100 120V only 8 devices may be connected together in this manner From the 9th devices please connect to power supply to get power for the second link when t...

Page 15: ...ntrol signal This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this star...

Page 16: ...he display will show A XXX XXX representing the actual DMX address If the fixture is not receiving a DMX signal the display will flash A XXX XXX representing the actual DMX address If your fixture is...

Page 17: ...indicator on the display This indicator is designed to give a quick visual indication of the fixtures DMX status The illustration below details the functionality of the LED indicators The LED indicato...

Page 18: ...OCK ON OFF Key lock Press the MENU button for 3 seconds to activate CHAN 5CH 10CH DMX channel Mode FAIL OFF HOLD AUTO Status while there is no DMX DFSE ON OFF Default setting POHO ON OFF Preserves man...

Page 19: ...internal power source that should last about five years VALU Display the DMX 512 value of each channel With this function you can display the DMX 512 value of each channel The display will automatica...

Page 20: ...for better visualization when the fixture is mounted in an inverted position D ON The display is designed to turn off during normal operation to avoid excessive light in situations that require an ext...

Page 21: ...output 2 HOLD which will hold the last DMX command or 3 AUTO which will put the fixture in sound active mode DFSE Restore Default This function is used to restore the factory settings of the device A...

Page 22: ...ar Fixture Run Time This function resets the run time to zero 9 5 Edit Internal Program Settings The fixture comes equipped with a built in DMX recorder that allows custom programs to be installed and...

Page 23: ...stands for Channel 11 of the editing scene the DMX value is XX 6 Adjust the DMX value by tapping the UP button until you get the expected effect for this channel 7 Press ENTER to enter the editing of...

Page 24: ...1 by pressing the UP or DOWN buttons 3 Press MODE ESC the display shows SC01 4 Press MODE ESC the display shows C 01 5 Select CEDT by pressing the UP or DOWN buttons 6 Press MODE ESC the display shows...

Page 25: ...Channel mode In this mode channel 1 controls all the cool white LEDs channel 2 controls all the warm white LEDs channel 3 controls the color_temperature channel 4 controls the strobe and channels 5 c...

Page 26: ...No function shutter open Channel 5 dimming 0 255 Dimming 0 Black 255 100 10 Channel Mode This chart details a simple layout of the DMX channel assignment in CHANNEL 1 Cool white CHANNEL 2 Warm white C...

Page 27: ...6 Warm White 0 255 Warm White group3 Channel 7 Cool White 0 255 Cool White group4 Channel 8 Warm White 0 255 Warm White group4 Channel 9 Strobe 1 95 Strobe effect slow to fast 96 127 No function shutt...

Page 28: ...rial fatigue or sediments Never remove the ground prong from the power cable Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety...

Page 29: ...with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number ha...

Page 30: ...ing warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fi...

Page 31: ...ELAR DW BRICK Elation Professional Los Angeles Ca 30 www ElationLighting com 13 PHOTOMETRIC DATA...

Page 32: ...ELAR DW BRICK Elation Professional Los Angeles Ca 31 www ElationLighting com 14 DIMENSIONAL DRAWINGS...

Page 33: ...ELAR DW BRICK Elation Professional Los Angeles Ca 32 www ElationLighting com 15 CHANGE LENS TO GET DIFFERENT BEAM ANGLES...

Page 34: ...ELAR DW BRICK Elation Professional Los Angeles Ca 33 www ElationLighting com 16 CIRCUIT SCHEMATIC...

Page 35: ...e Standard DMX 512 3 pole XLR Pin 3 Pin 2 Ground Pin 1 or Standard DMX 512 5 pole XLR n a Pin 5 n a Pin 4 Pin 3 Pin 2 Ground Pin Color Mixing Cool white and Warm white Color Additive Mixing Beam Angle...

Page 36: ...Rev 01 06 2011 Version 1 3 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighitng com...

Reviews: