Rev 3/05
CMY ZOOM 250
Elation Professional
4295 Charter Street
Los Angeles, Ca 90058
www.elationlighting.com
Page 1: ...Rev 3 05 CMY ZOOM 250 Elation Professional 4295 Charter Street Los Angeles Ca 90058 www elationlighting com...
Page 2: ...arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer without first con...
Page 3: ...properly handled Never touch the lamp with your bare hands as the oil from your hands will shorten lamp life Also never move the fixture until the lamps have had ample time to cool Remember lamps are...
Page 4: ...ture fitted with a gas discharge lamp Never open this fixture while in use During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a norma...
Page 5: ...nt Allow at least 30 minutes after disconnecting main power before you open the CMY ZOOM 250 To prevent personal injury never touch the lamp if you are not absolutely sure it has cooled 5 Never look d...
Page 6: ...he device during operation The housing may heat up Please be aware that damages caused by manual modifications to the device are not subject to warranty Keep away from children and non professionals G...
Page 7: ...he base of the fixture If you use the quick lock cam in hanging up the fixture please make sure the 4 quick lock fasteners turned in the quick lock holes correctly Operate the device only after having...
Page 8: ...speed in both directions Macro function for combinations between CMY color mixture and color wheel Frost filter for softer beam Beam shape effect wide and flat beam can steplessly be rotated by 180 S...
Page 9: ...Housing screws 4 Control Board 5 Mounting bracket 6 Fixation screw 5 4 6 3 2 1 Rear panel 7 Ventilation fan 8 DMX In socket 9 DMX Out socket 10 Lamp system 11 Power supply 12 Fuseholder 13 Power switc...
Page 10: ...se a cloth to handle the lamps during insertion and removal Do not install lamps with a higher wattage They generate higher temperatures than which the device was designed for For the installation you...
Page 11: ...re below for proper lamp optimization 1 Using either a DMX controller or the control panel on the unit strike the lamp set the dimmer intensity to 100 and focus the light on a flat surface beam open w...
Page 12: ...s Angeles Ca 90058 CMY ZOOM 250 Do not operate this device with open cover Please remember the lamp is not a hot restrike type you must wait approximately 10 minutes after having turned the lamp off b...
Page 13: ...vicing the fixture Before taking into operation for the first time the installation has to be approved by an expert Cautions Be sure to install this fixture outside any areas where persons may reach i...
Page 14: ...s point and never secure a safety cable to a carrying handle Clamps The CMY ZOOM 250 has been designed to hold multiple clamps to the bottom of the unit in several different orientations Always use an...
Page 15: ...hat DMX cable must be daisy chained and can not be split Be sure to follow the above figure when making your own cables Do not use the ground lug on the XLR connector Do not connect the cable s shield...
Page 16: ...e in your daisy chain to terminate the line Using a cable terminator Elation part number Z DMX T will decrease the possibilities of erratic behavior projector 1 projector 2 projector 3 starting addres...
Page 17: ...starting address for all fixtures or a group of fixtures or make different address for each fixture individually If you set the same address all the units will start to listen to the same control sig...
Page 18: ...XXX XXX representing the actual DMX address If the fixture is not receiving DMX signal the display will flash A XXX XXX representing the actual DMX address This situation can occur if the 3 PIN XLR pl...
Page 19: ...511 Indicates the staring DMX address A001 also is the setting for slave 2 TEST T 01 T XX Automatically test the function MSTR Runs fixture as master for audio 3 AUDI ALON Runs fixture as alone for au...
Page 20: ...but only channels 1 2 3 4 and 6 can be tested 3 AUDI MENU MAST Master Runs the unit as master in sound active mode ALON Alone Runs the unit stand alone sound active mode 4 LAMP MENU ON OFF Manually s...
Page 21: ...Lamp delay on time SPOT This provides a spot beam for better lamp optimization DFSE Default Resets the unit to default VER Version Displays the software version 10 EDIT MENU RUN This will run your ow...
Page 22: ...current DMX address immediately after the reset sequence If the fixture is not receiving a DMX signal the display will flash continuously To set or adjust a DMX address please follow the procedure bel...
Page 23: ...AUDI MAIN MENU MSTR Define the unit as the master in master slave mode 1 Access the main menu 2 Tap the UP button until AUDI is displayed press MODE ENTER 3 Tap the UP button until MSTR is displayed...
Page 24: ...ion the fixture will only reset the color wheel motor 1 Access the main menu 2 Tap the UP button until RESE is displayed press MODE ENTER 3 Tap the UP button until COLR is displayed press MODE ENTER t...
Page 25: ...s EXIT to return to the main menu CLMP With this function you can clear the running time of the lamp Note Very Important Please clear the lamp time every time you replace the lamp 1 Access the main me...
Page 26: ...d 3 Press MODE ENTER the display will show VALU 4 Press MODE ENTER once again d 00 will be displayed 5 Press MODE ENTER to confirm 6 Press EXIT to return to the main menu D ON This function will turn...
Page 27: ...ayed press ENTER 3 Tap the UP button until LADJ is displayed press ENTER 4 The display will show ON OFF 5 Press the UP button to select ON to activate this function or OFF to deactivate this function...
Page 28: ...N With the function RUN you can run your pre made program You can set the number of steps under Step S 01 S 48 You can edit the individual scenes under Edit 1 Access the main menu 2 Tap the UP button...
Page 29: ...ved in Edit 5 Press ENTER to save and exit Editing procedure 1 Using the control board only 1 Access the main menu 2 Tap the UP button until EDIT is displayed Press MODE ENTER 3 The display will show...
Page 30: ...settings for the scene you are editing the display will change to the next scene automatically 13 Repeat steps 3 12 to edit other scenes you can edit and save 48 scenes maximum 14 Press EXIT to exit n...
Page 31: ...sfully downloaded the rst scene 9 Adjust the Step time needed by pressing the UP button 10 Call up the second scene in your controller now 11 Repeat steps 3 6 until all desired scenes are downloaded 1...
Page 32: ...n 0 white 255 100 Cyan Channel 3 Magenta Color Wheel 0 255 Magenta 0 white 255 100 magenta Channel 4 Yellow Color Wheel 0 255 Yellow 0 white 255 100 Yellow Channel 5 Shutter strobe 0 31 Shutter closed...
Page 33: ...8 95 Macro11 216 223 96 103 Macro12 224 231 104 111 Macro13 232 239 112 119Macro14 240 247 120 127Macro15 248 255 Channel 10 Speed Of CMY And Dimmer 0 225 Speed Max Min 226 235no function 236 245max s...
Page 34: ...Elation Professional Los Angeles Ca 90058 CMY ZOOM 250 140 159Internal program 3 160 179Internal program 4 180 199Internal program 5 200 219Internal program 6 220 239Internal program 7 240 255Auto pro...
Page 35: ...ly but if the fixture has less than 3 errors only the channels which have errors can not work properly others can work as usual 01Er Color wheel error This message will appear after the reset of the f...
Page 36: ...must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage have to be a...
Page 37: ...with the product If any accessories are shipped with the product Elation Professional shall have no liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof...
Page 38: ...rofessional in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or imp...
Page 39: ...supply 120V 60Hz Power consumption 400W Lamp MSD250 GY9 5 socket Metal Halide Motors 8 motors Packing dimensions 49x36x48cm Net weight 16KGS Gross weight 18KGS Remark errors and omissions for every i...
Page 40: ...ZOOM 250 Elation Professional Los Angeles Ca 90058 CMY ZOOM 250 Elation Professional 4295 Charter Street Los Angeles CA 90058 323 582 3322 323 582 3108 fax www ElationLighting com info ElationLighitng...