background image

SIXPAR 100IP™

user manual

Summary of Contents for 1236100102

Page 1: ...SIXPAR 100IP user manual ...

Page 2: ...r reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW Kerkrade The Netherl...

Page 3: ...mited Warranty USA Only 5 Safety Guidelines 6 Overview 8 Installation 10 DMX Setup 13 System Menu 15 Dimmer Mode 17 DMX Channel Functions and Values 18 Maintenance Guidelines 20 Specifications 21 Optional Accessories 23 CONTENTS ...

Page 4: ...e subject to any warranty claims and or repairs Ensure all connections and end caps are properly sealed with a non conductive dielectric grease available at most electrical suppliers to prevent water ingress condensation and or corrosion OPTIONAL CORROSION RESISTANT COATING Optional Corrosion Resistant Coatings may be available for this fixture Please consult your Elation Professional sales repres...

Page 5: ...t its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional All products covered by this warranty were manufactured after January 1...

Page 6: ...TECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURER S WARRANTY DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURE S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND OR REPA...

Page 7: ...operate fixture if the power cord is frayed crimped damaged and or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease NEVER force a power cord connector into the fixture If the power cord or any of its connectors are damaged replace it immediately with a new one of similar power rating DO NOT block any air ventilation slots All fan and air inlets ...

Page 8: ...8 OVERVIEW POWER IN DMX IN DMX OUT Power Out Valve System Menu LCD Controls S Knobs to tighten Brackets Yokes Mounting Brackets Yokes Lens ...

Page 9: ...e wrench not included TORQUE SETTING 11 lbf in 12 7kgf cm lbf in Pound Force Inches kgf cm Kilogram Force Centimeters CAUTION DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT TEST FIXTURE USING THE ELATION IP TESTER CONTACT ELATION SERVICE FOR MORE DETAILS ...

Page 10: ...face a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture clamps cables and accessories Overhead rigging requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation...

Page 11: ...ed through the center hole of the closed dual yokes The dual yokes of the fixture provides a rigging point for a SAFETY CABLE not included Be sure to only use one of the designated rigging points for the safety cable and never secure a safety cable to a carrying handle SAFETY CABLE ALWAYS ATTACH AN APPROPRIATELY RATED SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSU...

Page 12: ...nd periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury POWER AND DATA CABLES TO MAINTAIN THE IP65 RATING INTEGRITY OF THE FIXTURE ALL CABLES MUST BE RUN TOWARDS THE GROUND TO PREVENT WATER ACCUMULATION AROUND THE CONNECTIONS CABLES ...

Page 13: ...signed to address 1 to that fixture no matter where it is located in the DMX chain The SIXPAR 100IP can be controlled via DMX 512 protocol and the DMX address is set via the control menu DMX Cable REQUIREMENTS For DMX and Primary Secondary Operation Your fixture and your DMX controller require a standard 3pin or 5pin XLR connector for data input and data output Also remember that a DMX line must b...

Page 14: ...l the fixtures simultaneously If a different DMX address is set for each fixture each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the SIXPAR 100IP when in the 12 Channel Mode you should set the starting DMX addr...

Page 15: ...o 06 07 08 or 12 Pressing the ENTER button once will confirm your selected value Exit at any time without making any adjustments by pressing the MODE button INFORMATION DISPLAYED DURING INITIAL POWER ON When the fixture is initially powered ON the display shows the following information Update Wait SIXPAR 100IP 100IP V1 03 Fixture Software Version LCD CONTROL PANEL LOCKOUT When the Display ON menu...

Page 16: ...ss 00 99 B00 99 Adjust BLUE Brightness 00 99 W00 99 Adjust WHITE Brightness 00 99 A00 99 Adjust AMBER Brightness 00 99 U00 99 Adjust UV Brightness 00 99 S00 99 Adjust STROBE SPEED 00 SLOW 0 1Hz 99 FAST 20Hz 2 CHANGE 30 Color Chase Macro SP01 99 Adjust SPEED 01 SLOW 99 FAST S00 99 Adjust STROBE SPEED 00 SLOW 0 1Hz 99 FAST 20Hz 3 CHANG6 6 Color Chase Macro SP01 99 Adjust SPEED 01 SLOW 99 FAST S00 99...

Page 17: ...17 DIMMER MOD E ...

Page 18: ...NO STROBE 128 159 Strobe Pulse Effect in Sequence SLOW to FAST 160 191 LED ON NO STROBE 192 223 Random Strobe Effect SLOW to FAST 224 255 LED ON NO STROBE 9 COLOR MACROS 0 3 OFF 4 7 RED 8 11 GREEN 12 15 BLUE 16 19 WHITE 20 23 AMBER 24 27 UV 28 31 RED GREEN 32 35 RED BLUE 36 39 RED BLUE 40 43 RED AMBER 44 47 RED UV 48 51 GREEN BLUE 52 55 GREEN WHITE 56 59 GREEN AMBER 60 63 GREEN UV 64 67 BLUE WHITE...

Page 19: ... 188 191 RED GREEN AMBER UV 192 195 RED BLUE WHITE AMBER 196 199 RED BLUE WHITE UV 200 203 RED BLUE AMBER UV 204 207 RED WHITE AMBER UV 208 211 GREEN BLUE WHITE AMBER 212 215 GREEN BLUE WHITE UV 216 219 GREEN BLUE AMBER UV 220 223 GREEN WHITE AMBER UV 224 227 BLUE WHITE AMBER UV 228 231 RED GREEN BLUE WHITE AMBER 232 235 RED GREEN BLUE WHITE UV 236 239 RED GREEN BLUE AMBER UV 240 243 RED GREEN WHI...

Page 20: ...tion service technician Should you need any spare parts please order genuine parts from an authorized Elation dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tightened at ...

Page 21: ... LCD Menu Display IP DMX In Out IP Power In Out With Wired Digital Communication Network SIZE WEIGHT Length 10 1 257mm Width 6 2 158mm Vertical Height 9 6 243mm Weight 9 5 lbs 4 3 kg ELECTRICAL THERMAL AC 110 250V 50 60Hz 89W Max Power Consumption Power Linking 12pcs 110V 25pcs 240V 5 F to 113 F 15 C to 45 C UV Wavelength 395nm APPROVALS RATINGS CE cETLus IP65 INCLUDED ITEMS Male Edison to IP Fema...

Page 22: ...22 DIMENSION S Drawings not to scale Specifications and improvements in the design of this unit and this manual are subject to change without notice PHOTOMETR IC DATA ...

Page 23: ...ween the device and the receiver Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected Consult the dealer or an experienced radio TV technician for help Energy Saving Matters EuP 2009 125 EC Saving electric energy is a key to help protecting the environment Please turn off all electrical products when they are not in use To avoid power consump...

Page 24: ......

Reviews: