4.3
E
LECTRICAL CONNECTION
To connect your sign to the power supply, an outlet is provided. The installer must connect the
outlet to the power grid as shown below:
For power through the permanent mains network or the street lighting system, the Evolis is
supplied with: - A 4Ah transformer - A 12V / 22Ah battery - IP66 male plug pre-cabled into the
Evolis - IP66 female plug for connection to the mains electricity supply Connect the FEMALE
plug to the mains electricity supply: - Wire the neutral wire (commonly blue colour) cable on the
"N" - Wire the live wire (commonly brown colour) on the "1" - Wire the earth wire (commonly
green/yellow) on the CENTRE connection - The other two prongs in the plugs are not used -
Then, simply plug the Evolis into the mains by plugging the male plug into the female. The plugs
are equipped with a twist mechanism that not only renders them waterproof but also prevents
them from being pulled apart.
Don’t forget to activate this final twist before use.
The only difference between the permanent mains and the mains street lighting schema is that
the street light system requires the addition of a battery whereas the permanent mains system
does not (apart from instances where there is a localised power cut) . Under the street lighting
system,the Evolis will still function without a battery but ONLY during the hours that the street
lighting is functioning. With a battery added, it will charge during street lighting hours and then
take over as a power source from the street lighting as soon as daylight hours dictate that they
are switched off.
WARNING :
The electrical installation to which your device is connected must meet your local
current applicable standards. ELAN CITY cannot be held responsible for damages
caused by poor quality installation.
The guarantee is void in the case of product
failure where a 30mA calibre 16A type circuit breaker has not been used
.
Live
1
Neutral
N
Earth
centre