E L A N H O M E S Y S T E M S
Page 44 © ELAN Home Systems 2009 • All rights reserved.
S128P
INSTALLATION MANUAL
VIA! Touch Panel Connections
If not using the SPP, it is necessary to use a PVIA Wall Plate when connecting VIA! Touch Panels to the S128P.
VIA! Touch Panels require the 16V power supplies that are included with each PVIA wall plate (PVIA1, PVIA4, and
PVIA10).
BLUE
WHITE/BLUE
ORANGE
WHITE/ORANGE
GREEN
WHITE/GREEN
BROWN
WHITE/BROWN
1
2
3
4
5
6
7
8
PIN # COLOR CODE
FRONT
CABLE
Standar d ELAN RJ-45 Pin-Out
TA B
S128P to PVIA1
To VIA!
Touch
Panel
PVIA1 (No SC1, SC4, or SS1)
GND
+16V
GND
SIR
Z485-
Z485+
ST/SN S
IR
V485-
V485+
+16V
White/Blue
Green
White/Orange
Br ow n
White/Blue
Orange
White/Orange
Gr een
White/Gr een
Br ow n
White/B ro wn
N/C
N/C
N/C
S128P to PVIA4/PVIA10
To VIA!
Touch
Panel
GND
+16V
GND
ST/SN S
IR
485-
485+
+16V
Green
White/Orange
Brown
White/Blue
Orange
White/Orange
Gr een
White/Green
Br own
White/Brown
VIA1
IR
XLINK
Z485-
Z485+
IR1
GND
ST1
ST2
ST3
ST4
SIR
GND
IR2
GND
IR3
GND
IR4
GND
White/Blue
To S128P
Zone 1
PVIA4/PVIA10 (Zone 1 Connection Shown)
Blue
Blue
Blue
To S128P
Figure 3-27: VIA! Touch Panel Connections (No SPP)
S128P.indd 44