EL EL4855 Installation Instructions Download Page 1

 

Wireless 2-Way PIR / PET 

Camera Detector 

 

Models: 

EL4855/EL4855P

  

EN

 

Installation Instructions 

Description 

The

 

EL4855/EL4855PI

 

is

 

a

 

battery

 

powered

 

2

Way

 

wireless

 

PIR/PET

 

detector

 

that

 

includes

 

an

 

integrated

 

camera

 

for

 

visual

 

verification

 

and

 

is

 

compatible

 

with

 

all

 

Electronics

 

Line

 

2

Way

 

security

 

systems.

 

Features include: 

 

14m

 

coverage

 

(wide

 

angle)

 

with

 

90°

 

field

of

view

 

 

Installation

 

height

 

2.4m

 

 

VGA

 

or

 

QVGA

 

camera

 

resolution

 

 

Discreet

 

IR

 

flash

 

allows

 

imaging

 

in

 

complete

 

darkness,

 

up

 

to

 

10m

 

(33’)

 

 

Sequence

 

of

 

images

 

upon

 

event,

 

configurable

 

number

 

and

 

fps

 

 

During

 

disarm,

 

events

 

are

 

ignored

 

to

 

save

 

battery

 

and

 

for

 

privacy

 

 

On

demand

 

images

 

initiated

 

from

 

authorized

 

Smartphone

 

or

 

web

 

browser

 

 

Two

 

RF

 

channels

 

with

 

separate

 

antennas:

 

One

 

for

 

control,

 

second

 

channel

 

for

 

image

 

transmission

 

 

Images

 

stored

 

on

 

detector

 

until

 

transmission

 

to

 

panel

 

complete

 

 

2

 

long

life

 

lithium

 

batteries

 

for

 

extended

 

battery

 

life

 

 

Frequency:

 

868Mhz

 

or

 

433Mhz

 

 

PET

 

Immunity

 

option

 

(45Kg

 

animals)

 

Installation 

Step1: Selecting a Mounting Location 

Select

 

the

 

mounting

 

location

 

for

 

best

 

coverage

 

of

 

the

 

area

 

that

 

is

 

to

 

be

 

protected

 

(see

 

Preliminary

 

Considerations

 

and

 

Coverage

 

Patterns

).

 

Step 2: Registering the Detector in the 
System 

The

 

detector

 

must

 

identify

 

itself

 

to

 

the

 

system’s

 

receiver

 

(control

 

panel)

 

during

 

the

 

registration

 

process.

 

1.

 

 

Set

 

the

 

system

 

to

 

registration

 

mode.

 

2.

 

 

Go

 

to

 

the

 

main

 

menu

 

and

 

select

  

[9]

 

Programming

 

>

 

[1]

 

Devices

 

>

 

[1]

 

Zones.

 

3.

 

 

Select

 

a

 

zone

 

and

 

press

 ʹ

ʹ

.

 

The

 

system

 

enters

 

into

 

Learn

 

mode.

 

4.

 

 

Unlock

 

and

 

remove

 

the

 

mounting

 

bracket

 

from

 

the

 

detector

 

(

see

 

Figure

 

1

 

and

 

Figure

 

3

).

 

Insert

 

the

 

supplied

 

batteries

 

into

 

the

 

battery

 

holders

 

paying

 

attention

 

to

 

the

 

correct

 

polarity

 

or

 

remove

 

the

 

plastic

 

protector

 

strip

 

if

 

the

 

batteries

 

are

 

already

 

in

 

place

 

(

see

 

Figure

 

3

).

 

The

 

detector

 

sends

 

a

 

transmission

 

to

 

the

 

system.

  

If

 

the

 

transmission

 

is

 

successfully

 

received

 

by

 

the

 

system

 

it

 

plays

 

a

 

confirmation

 

sound.

 

If

 

no

 

confirmation

 

sound

 

is

 

heard,

 

send

 

another

 

transmission

 

by

 

pressing

 

and

 

releasing

 

the

 

tamper

 

switch

 

of

 

the

 

device

 

(

see

 

Figure

 

3

).

 

Once

 

the

 

detector

 

is

 

successfully

 

registered

 

the

 

system

 

display

 

shows:

 

Save?

 

5.

 

 

Press

 

 

to

 

confirm

 

and

 

continue

 

entering

 

other

 

parameters

 

for

 

the

 

chosen

 

device

 

(see

 

Parameter

 

Configuration

).

 

Step 4: Mounting the Detector 

The

 

detector

 

must

 

be

 

tested

 

on

 

the

 

exact

 

mounting

 

position

 

before

 

permanently

 

mounting.

 

1.

 

 

Open

 

the

 

knockout

 

holes

 

of

 

the

 

mounting

 

bracket,

 

and

 

use

 

them

 

as

 

a

 

template

 

for

 

mounting

 

(

see

 

Figure

 

2

).

 

For

 

Pet

 

friendly

 

model:

 

In

 

order

 

to

 

optimize

 

pet

 

immunity,

 

always

 

mount

 

the

 

detector

 

vertically

 

at

 

a

 

right

 

angle

 

to

 

the

 

floor.

 

Make

 

sure

 

that

 

an

 

animal

 

cannot

 

get

 

above

 

the

 

height

 

of

 

1.5m

 

(5

ʹ

)

 

by

 

climbing

 

on

 

furniture,

 

shelving

 

or

 

stairs.

 

2.

 

 

Once

 

the

 

bracket

 

is

 

installed,

 

slide

 

and

 

lock

 

the

 

detector

 

onto

 

the

 

mounting

 

bracket.

 

3.

 

 

Perform

 

a

 

Walk

 

Test

 

(see

 

Performing

 

a

 

Walk

 

Test

).

 

4.

 

 

Insert

 

and

 

fasten

 

screw

 

into

 

the

 

hole

 

located

 

at

 

the

 

bottom

 

of

 

the

 

detector

 

to

 

lock

 

the

 

detector

 

to

 

the

 

mounting

 

bracket

 

(

see

 

Figure

 

4

).

 

Step 5: Performing a Walk Test 

NOTE:

 

The

 

detector

 

needs

 

approximately

 

90

 

seconds

 

to

 

warm

 

up

 

after

 

applying

 

power.

 

Go

 

to

 

the

 

systems

 

main

 

menu

 

and

 

select

 

[7]

 

Service

 

>

 

[6]

 

Walk

 

Test

 

and

 

press

 ʹ

.

 

During

 

Walk

 

Test

 

mode,

 

walk

 

through

 

the

 

entire

 

field

 

of

 

view

 

of

 

the

 

detector

 

and

 

confirm

 

that

 

the

 

LED

 

activates

 

and

 

deactivates

 

accordingly

 

(

see

 

LED

 

Indication

).

  

 

Verify

 

that

 

the

 

system

 

receiver

 

also

 

receives

 

the

 

signals.

 

NOTE:

 

Wait

 

for

 

ten

 

seconds,

 

after

 

each

 

detection,

 

before

 

continuing

 

the

 

test.

 

After

 

completing

 

the

 

walk

 

test,

 

reset

 

the

 

system

 

to

 

Normal

 

mode.

 

LED Indication 

The

 

LED

 

indicator

 

is

 

lit

 

every

 

time

 

a

 

transmission

 

is

 

made.

 

To

 

enable/disable

 

LED

 

indication,

 

refer

 

to

 

Parameter

 

Configuration

 

section.

 

Parameter Configuration 

2

Way

 

parameters

 

can

 

be

 

modified

 

from

 

the

 

system.

 

Go

 

to

 

the

 

main

 

menu

 

and

 

select

 

[9]

 

Programming

 

>

 

[1]

 

Devices

 

>

 

[1]

 

Zones

 

>

 

[11].Sensor

 

Par.

 

LED:

 

Enable*

 

/

 

Disable

 

PIR

 

Sensitivity:

 

Low*

 

/

 

High

 

Alarm

 

Delay:

 

1

20

 

minutes

 

(3

 

mins.*)

 

Camera

 

Resolution:

  

QVGA

 

(320X240)*,

  

VGA

 

(640X480)

 

Color:

 

Color*

 

/

 

B&W

 

Compression:

 

Low*

 

/

 

High

 

Flash:

 

Enable

 

/

 

Disable*

 

#

 

of

 

Pictures:

 

1

9

 

(3*)

 

#

 

of

 

Different

 

Pictures.

 

1

9

 

(0*)

 

Picture

 

Delay:

 

0

450

 

ms

 

(480

 

ms*)

 

User

 

Monitor:

 

Enable*

 

/

 

Disable

 

Zone

 

Assignment:

 

Any

 

of

 

up

to

 

four

 

zones

 

can

 

trigger

 

a

 

picture

 

capture

 

(00

00

00

00*).

 

Medical

 

Trigger:

 

Enable

 

/

 

Disable*

 

Panic

 

Trigger:

 

Enable

 

/

 

Disable*

 

Fire

 

Trigger:

 

Enable

 

/

 

Disable*

 

*

 

=

 

default

 

For

 

additional

 

information

 

refer

 

to

 

the

 

System

 

Installer

 

Manual

.

 

Camera Test and Snapshot Events 

A

 

camera

 

test

 

image

 

can

 

be

 

taken

 

using

 

web/smartphone

 

apps

 

on

 

systems

 

supporting

 

these

 

applications.

 

Snapshot

 

events

 

detected

 

by

 

the

 

PIR

 

camera

 

are

 

recorded

 

into

 

the

 

camera’s

 

memory.

 

The

 

event

 

record

 

consists

 

of

 

the

 

date

 

and

 

time

 

stamp,

 

a

 

detailed

 

description

 

of

 

the

 

event

 

including

 

its

 

source

 

and

 

an

 

image

 

record.

 

Diagnostics 

You

 

can

 

perform

 

diagnostic

 

tests

 

on

 

your

 

detector

 

using

 

the

 

system

 

receiver.

 

Diagnostics

 

includes

 

testing

 

the

 

detector

 

battery

 

status

 

and

 

communication

 

between

 

the

 

detector

 

and

 

the

 

system.

  

For

 

additional

 

information

 

refer

 

to

 

the

 

System

 

Installer

 

Manual

.

 

Battery Replacement 

1.

 

 

Unlock

 

and

 

slide

 

the

 

detector

 

from

 

the

 

mounting

 

bracket.

 

2.

 

 

Replace

 

the

 

batteries

 

paying

 

attention

 

to

 

the

 

correct

 

polarity.

 

3.

 

 

Slide

 

and

 

lock

 

the

 

detector

 

to

 

the

 

mounting

 

bracket.

 

CAUTION

 

 

Risk

 

of

 

explosion

 

if

 

battery

 

is

 

replaced

 

by

 

an

 

incorrect

 

type.

 

Dispose

 

of

 

used

 

batteries

 

according

 

to

 

local

 

regulations.

 

 

Specifications 

Electrical

Battery

 

Type:

 

2

 

x

 

CR

 

123,

 

3V

 

Lithium

 

Battery

 

Life:

 

2

 

batteries

 

 

3

 

year

 

typical

 

lifetime

 

Current

 

Consumption:

 

58

 

A

 

standby;

 

200

 

mA

 

max.

 

peak

 

at

 

capture

 

with

 

flash

 

Supervision

 

Transmission:

 

10

 

minutes

 

RF

 

transmitting

 

frequencies:

 

868MHz,

 

433MHz

 ‐ 

models

 

EL5855

 

and

 

EL5855PI

 

Optical

Filtering:

 

White

 

Light

 

Protection

 

Pet

 

friendly:

 

Up

 

to

 

a

 

45

 

kg

 

animal

 

immunity

 

(pet

 

model)

 

Physical

Size

 

(L

 

x

 

W

 

x

 

D):

 

120

 

x

 

65

 

x

 

35

 

mm

 

(4.7

 

x

 

2.6

 

x

 

1.8

 

in)

 

Weight:

 

100

 

grams

 

(3.52

 

oz.)

 

Environmental

RF

 

Immunity:

 

According

 

to

 

EN50130

4

 

Operating

 

Temperature:

 

10

C

 

a

 

55

C

 

(14

F

 

a

 

140

F)

 

Storage

 

Temperature:

 

20

C

 

a

 

60

C

 

(

4

F

 

a

 

140

F)

 

Camera

Type:

 

CMOS

 

digital

 

image

 

sensor

 

Lux:

 

0

 

Lux

 

(total

 

darkness)

 

View

 

Angle:

 

H

 

90

 

V

 

73

 

 

Preliminary Considerations 

  

Do

 

not

 

install

 

outside

 

 

Do

 

not

 

install

 

near

 

windows

 

 

Do

 

not

 

install

 

near

 

vents

 

(air,

 

heat,

 

or

 

AC)

 

 

Do

 

not

 

install

 

near

 

ceiling

 

fans

 

 

Do

 

not

 

install

 

in

 

extreme

 

temperatures

 

 

Do

 

not

 

install

 

in

 

direct

 

sunlight

 

 

Ok

 

for

 

sites

 

with

 

small

 

pets

 

 
 

 

 

 

PIR Coverage Patterns 

PIR

 

Model

 

 

PET

 

Model

 

 

 

 

Camera Coverage 

Side

 

View

 

Top

 

View

 

 

 

 

 

Reviews: