The EL-4601 is a 2-Way magnetic door and window contact designed for use with the iConnect 2-Way 
security system. 
  

1.Magnet 

2.Antenna 

3.Battery Holder 

4.LED Indicator 

5.Reed switch 

6.Tamper Switch 

7.Location of Wiring Knockout 

8.PCB Release Tab 

 

Registration  

The EL-4601 must identify itself to the iConnect 2-Way receiver as follows: 

1. 

Set the system to registration mode.  

a.  Go to the main menu and select [9]>[1]>[1] (Programming > Devices > Zones) 
b.  Select a zone and press '√'.  

2. 

Open the detector housing. 

3. 

Remove the divider separating the battery from the contacts on the battery holder. The detector will 
send a transmission. If the transmission is successfully received by the system it will play a 
confirmation sound. If no confirmation sound is heard send another transmission by pressing and 
releasing the tamper switch of the device.  

Note: Due to the occurrence of voltage delay in lithium batteries that have been in storage, 
the batteries may initially appear to be dead. In this case, leave the unit in Test mode for a few 
minutes until the battery voltage level is stabilized

 

4. 

As soon as 'Save?' appears press '√'. 

Wall Mounting 

After the detector has been registered mount the detector as follows: . 

Note: Before permanently mounting the unit, test the transmitter from the exact mounting 
position. If necessary, improve the position of the transmitter. Note: The alarm is generated 
by magnet removal at 24 (+/- 0.5) mm and is cleared by magnet approach at 22 (+/- 0.5) mm 

1.  Open the detector housing. 
2.  Remove the PCB by pressing the PCB release tab.   

Note: When handling the PCB, do not apply pressure on the antenna

 

3.  Mount the back cover using two screws and replace the PCB. 

Use ISO 7050 (ST3.5 x 22) or similar countersunk screws so 
that the screw head will not touch the PCB – see Figure 2.  

Note: The upper screw is also used for back tamper. When 
the detector is removed from the wall, the screw causes the 
tamper release to break away from the back cover and the 
rear tamper switch is released

4.  Open the magnet housing. 
5.  Mount the back cover of the magnet using two screws.  

 

PCB 

FIGURE 2