CAUTION!

A circuit breaker (250VAC, 10A) type C according to 
EN60898-1 of load shall be installed in the fixed wiring for
protection.
Do not mount on conductive surface. 
Do not open the enclosure frequently.
Turn off power when change the light sources.
High in-rush current would be caused when bulbs of certain 
brands burned which might damage the unit permanently.  

1

 PACKAGE CONTENTS

 

Pattern

Pattern

Item

Item

Quantity

Quantity

1

3

Please disconnect power completely and read the 
entire instruction manual carefully before installation.

3

 INSTALLATION AND WIRING 

Top view

Side view

FIG.1-A

2

 PRODUCT DESCRIPTION

2.1 Features

3.1 Select a proper location

Motion 
detector

Lens shield

(

OS-360 / 300PA

)

3.1.1 It is recommended to install the detector at the height of 
         2.5m. The detection range can reach up to a radius of
         16m at the height of 2.5m (See FIG.2-A & FIG.2-B).

Installation and assembly of electrical equipment
must be carried out by qualified electricians. 
Contact a qualified electrician in the event of fault 
or break down.

INSTRUCTION MANUAL

TECHNICAL SPECIFICATIONS

220-240V~ 50/60Hz

Rated Voltage

Load              

3.1.2.3 Pay attention to the walking direction in the test 
            proceeding (See FIG.4).

3.4 Installation procedure

This outdoor motion detector can be installed on wall directly & 
recess corner with mounting bracket or on the ceiling directly or  
on the European standard junction box.

FIG.9-A

Hook

Slot

When detector is standby under the auto mode, the 

 

can be bypassed to turn the light(s) on for 8 hours by series 
connecting a power supply switch.

detector

The operations are as under mentioned :

When the light is off, transfer the power supply switch from
“off 

→ 

on

 → 

off 

→ 

on” within 2sec, afterwards, light will 

change its status from on 3sec & off 2sec & on to confirm that 

 has entered into permanent on 8 hours mode.

detector
When the light is on, transfer the power supply switch “off 

→ 

 

→ 

off 

→ 

on” within 2sec, afterwards, light will turn off for 

2sec, then turns on to confirm that detector has entered into 

 on 8 hours mode.

on 

permanent

In the 

 on 8 hours mode, the 

 can be set to  

mode by transferring the power supply switch “off 

→ 

on”  

1sec, afterwards, light will turn off for 2sec. then detector 

enters into auto mode and work with the knob settings.

permanent

detector

auto 
within 

3.3 Wiring diagrams

3.3.1 Normal operation for lighting control (See FIG.5)

OUTDOOR PIR MOTION DETECTOR

for Lighting or HVAC Automation Control

OS-

 / OS-300PA / OS-

240PA

 

360PA

For lighting (with jumper wire)

Incandescent lamp: Max. 2300W
AC Halogen lamp : Max. 1200W
LV Halogen lamp  : Max. 1000VA / 
                               600W (Conventional)
                               Max. 900W (Electronic)
Fluorescent lamp  : Max. 1000VA / 600W
                               (uncompensated)
                               Max. 900VA / 100

µ

                               (compensated)
LED lamp(Driver)  : Max. 400W
Energy Saving       : Max. 600VA / 400W  
lamp                       (include CFL and PL lamp)

For HVAC (remove jumper wire)

Max.10A(cos

φ

=1) for    250VAC

Max.5A for    30VDC
Max.3A(cos

φ

=0.4) for    250VAC

OS-300PA

      

Lux                    
Adjustment

 Auto Off 
 Adjustment
 

Time 

  

 

Operating        

 

 

Temperature

o

o

-20 C to +50 C

Environmental   
Protection

IP55

Detection Range

OS-360PA

360° , up to  32m (R=16m) 
at height of 2.5m

Φ

300° , up to R16m (frontal)/R14m(backward)
at height of 2.5m

OS-240PA

      

240° , up to R16m 

 

at height of 2.5m

(frontal)/R8m(backward)

Adjustable from approx. 5sec to 30min 
and Test & 

Adjustable from approx. 5Lux to “    
and “    ” (learning range: 5Lux - 500Lux) 
& Holiday

” (

)

Can be used to control lighting or HVAC devices (voltage free
contact).
Pulse count function to avoid the false triggering problem 
caused by environment.
Excepting the provided Lux values, the ambient light level can 
be read-in as the Lux value for more flexible application.
Manual override for lighting on 8hrs. is enabled by using an 
external rocker switch to control or IR remote control.
Built-in 4 LEDs provide Warning / Watch function, which 
enables the detector to guarantee complete surveillance or 
warning respectively.
User friendly design of un-falling mounting base and plug-in 
terminal block for installation convenience. 

OS-360PA

Φ

32m

Φ

14m

Φ

10m

16m

O

360

2.2 Dimension (See FIG.1-A & FIG.1-B & FIG.1-C) 

Wall mount: 150 x 90 x 84mm

8

4m

m

7

9

mm

Φ

90mm

80mm

FIG.3

3.1.2.1 The optimal location for installation is at garden, corridor, 
             staircase, entrance, garage, public lavatory, outdoor 
             parking area, home and office, etc.  
3.1.2.2 Since the detector responds to temperature change, 
             please avoid the following conditions:

Avoid pointing the detector toward the objects whose surfaces 
are highly reflective, such as mirror, glass, etc.
Avoid mounting the detector near heat sources, such as heating
vents, air conditioners, lights, etc.
Avoid aiming the detector toward the objects which may be 
swayed in the wind, such as curtain, tall plants, etc.
             

3.1.2 Helpful tips for installation

OPEN

OPEN

FIG.2-A

FIG.2-B

OS-240PA 

OS-240PA /

 

OS-300PA /

 

OS-360PA

5

5

0

16m

16m

7

7

Top view

Side view

O

240

FIG.5

FIG.13

-

A

FIG.13

-

B

3.4.1.5 

                          

(See FIG.13-A) to shorten the detection range, or  

O

             turned leftward and rightward max. 90  horizontally  
             (See FIG.13-B). Please adjust detector head to get the  
             desired detection field.

Detector head can be adjusted downward max.40

FIG.11

FIG.12-A

FIG.12-B

Non-dropping 
screw

Bottom cover

Wall

 

mount

Ceiling

 

mount

Rubber
gasket

O

90

O

90

O

90

O

40

FIG.8

Anchor

Wood Screw

Φ

4x10mm

2

2

Wood Screw

Φ

4x25.4mm

2

Jump or wire

2

Lens shield
 (

OS-240PA

)

3.4.2 Corner / recess mount with mounting bracket

3.4.2.1 There are cable entry knock-outs at back and bottom 
             sides. Select the proper holes and break it through for 
             wiring. (See FIG.14-B & FIG.14-C)

 

3.4.2.2 Break the desired screw knock-outs (See FIG.14-A). Then  
             fix the mounting bracket onto recess/conner with wood 
             screws (See FIG.15-A& FIG.15-B), and fix bottom cover  
             on mounting bracket (See FIG.16). Refer to FIG.5-FIG.7
             to connect power cables, then fix the detector head to 
             the bottom cover and adjust the detector head to be in
             the correct position.

FIG.14-A

FIG.14-C

FIG.9-B

1

Corner 
mounting 
bracket

Pattern

Item

Quantity

Manual

1

Rubber
washer

Screw support

Cable entry
knock-out

Cable entry 
knock-out

3.4.1 Wall mount and ceiling mount

3.4.1.1 When installing, the junction box of detector can be stuck 
             on the bottom cover by inserting the hook into the slot, so 
             that you don’t need to hold the product on hand, to make 
             installation conveniently (See FIG.9-A & FIG.9-B & FIG.9-C)

.

3.4.1.2 Please strip off 6-8mm of cables sheathing by tool before 
             installation.
3.4.1.3 Feed the electric cables through rubber gasket 
             (see FIG.8) and refer to illustration of FIG.5 - FIG.7 for 
             correct wiring, then fit the bottom cover on the wall or 
             ceiling firmly by two screws (See FIG.10). 

The unique holiday mode for randomly switching ON / OFF
load is worked as a simple security function to protect your 
property.
The IR remote control is available for quick and convenient 
setting (for optional purchase).

Accessories for optional purchase

OS-240PA

 / 

OS-300PA

 / 

OS-360PA

3.2

.

3

 

Holiday function

FIG.15-A

Corner installation

µ

FIG.1-B

Wall corner mounting bracket 
(Optional purchase)

:

80  74

.

5  28mm

7

4

.5

m

m

80mm

28mm

5

5

0

16m

7

7

O

300

OS-300PA

Top view

Side view

FIG.4

Less sensitive to movement 
directly towards detector

More sensitive to movement 
across the detector

3.2.2 Manual override for switching light on for 8 hours
          (Lux is independent)

Under Auto mode, the load will turn on automatically when the 
movement is detected and the ambient light level is below the 
Lux setting value. When no movement is detected and the 
delay time has expired, the load will turn off automatically.

3.2.1 Auto mode

3.2 Function

3.3.3 For HVAC control (See FIG.7)

M

Manual
Switch

A1 

 

A2

Supply
Voltage

Fan

Heater

Contactor

Blue

Brown

Red

Red

N

N

N1

L

L

L1

D1

D2

Motion detector

FIG.7

3
             and adjust the detector head to be in the right position
            (See FIG.12

-

A & FIG.12-B)

.

.4.1.4 Fix the detector head to the bottom cover (See FIG.11)

FIG.10

6-8mm

FIG.14-B

150mm

6

6

mm

111

m

m

Φ

90mm

80mm

Ceiling mount:

Ceiling mount: 166 x 90 x 111mm

FIG.1-C

166mm

1

 

2

 

4

7

8

Set the Lux knob to “Holiday ” position, LED will flash quickly 
for 10sec, and then keep on for 10sec to indicate detector 
entering into Holiday mode. Detector is uncontrolled by Lux and 
Time under Holiday mode. 
    Under Holiday mode, the light will turn on automatically 
    when the ambient light level is below 50 Lux. Then the light
    will randomly turn ON and OFF between 10min to 1hr for the 
    next 4hrs. When the load is off, LED will flash by turns. When 
    the load is on, the 4 LEDs will flash simultaneously under this 
    mode.
    Exit Holiday mode: During the Holiday mode, adjust the 
    Lux knob to other positions beside “Holiday ”, load will 
    turn off and LED will flash for 5sec to indicate detector exiting 
    Holiday mode.

1-8 holes are 
s

crew 

knocku-outs

FIG.9-C

PASSIVE INFRA-RED SENSOR 

FOR AUTOMATION CONTROL

OUTDOOR PIR MOTION DETECTOR

for Lighting or HVAC Automation 

Control

OS-360PA OS-300PA  OS-240PA

Wall mount:

1s.

Load

Staircase timer

N

L

L

D1

D2

N

Motion detector

L

N

OUT

IN

μ

3.3.2 Staircase timer switch controlled by one sensor (Time should
         be set to       (See FIG.6).

1S.

Blue

Brown

Red

Red

FIG.6

N

L

5

5

0

16m

16m

7

7

Top view

Side view

O

180

Φ

10m

Φ

14m

Φ

32m

Φ

10m

Φ

14m

Φ

32m

Φ

10m

Φ

14m

Φ

32m

Φ

10m

Φ

14m

Φ

32m