
CAUTION!
A circuit breaker (250VAC, 10A) type C according to
EN60898-1 of load shall be installed in the fixed wiring for
protection.
Do not mount on conductive surface.
Do not open the enclosure frequently.
Turn off power when change the light sources.
High in-rush current would be caused when bulbs of certain
brands burned which might damage the unit permanently.
1
PACKAGE CONTENTS
Pattern
Pattern
Item
Item
Quantity
Quantity
1
3
Please disconnect power completely and read the
entire instruction manual carefully before installation.
3
INSTALLATION AND WIRING
Top view
Side view
FIG.1-A
2
PRODUCT DESCRIPTION
2.1 Features
3.1 Select a proper location
Motion
detector
Lens shield
(
OS-360 / 300PA
)
3.1.1 It is recommended to install the detector at the height of
2.5m. The detection range can reach up to a radius of
16m at the height of 2.5m (See FIG.2-A & FIG.2-B).
Installation and assembly of electrical equipment
must be carried out by qualified electricians.
Contact a qualified electrician in the event of fault
or break down.
INSTRUCTION MANUAL
TECHNICAL SPECIFICATIONS
220-240V~ 50/60Hz
Rated Voltage
Load
3.1.2.3 Pay attention to the walking direction in the test
proceeding (See FIG.4).
3.4 Installation procedure
This outdoor motion detector can be installed on wall directly &
recess corner with mounting bracket or on the ceiling directly or
on the European standard junction box.
FIG.9-A
Hook
Slot
When detector is standby under the auto mode, the
can be bypassed to turn the light(s) on for 8 hours by series
connecting a power supply switch.
detector
The operations are as under mentioned :
When the light is off, transfer the power supply switch from
“off
→
on
→
off
→
on” within 2sec, afterwards, light will
change its status from on 3sec & off 2sec & on to confirm that
has entered into permanent on 8 hours mode.
detector
When the light is on, transfer the power supply switch “off
→
→
off
→
on” within 2sec, afterwards, light will turn off for
2sec, then turns on to confirm that detector has entered into
on 8 hours mode.
on
permanent
In the
on 8 hours mode, the
can be set to
mode by transferring the power supply switch “off
→
on”
1sec, afterwards, light will turn off for 2sec. then detector
enters into auto mode and work with the knob settings.
permanent
detector
auto
within
3.3 Wiring diagrams
3.3.1 Normal operation for lighting control (See FIG.5)
OUTDOOR PIR MOTION DETECTOR
for Lighting or HVAC Automation Control
OS-
/ OS-300PA / OS-
240PA
360PA
For lighting (with jumper wire)
Incandescent lamp: Max. 2300W
AC Halogen lamp : Max. 1200W
LV Halogen lamp : Max. 1000VA /
600W (Conventional)
Max. 900W (Electronic)
Fluorescent lamp : Max. 1000VA / 600W
(uncompensated)
Max. 900VA / 100
µ
F
(compensated)
LED lamp(Driver) : Max. 400W
Energy Saving : Max. 600VA / 400W
lamp (include CFL and PL lamp)
For HVAC (remove jumper wire)
Max.10A(cos
φ
=1) for 250VAC
Max.5A for 30VDC
Max.3A(cos
φ
=0.4) for 250VAC
OS-300PA
Lux
Adjustment
Auto Off
Adjustment
Time
Operating
Temperature
o
o
-20 C to +50 C
Environmental
Protection
IP55
Detection Range
OS-360PA
360° , up to 32m (R=16m)
at height of 2.5m
Φ
300° , up to R16m (frontal)/R14m(backward)
at height of 2.5m
OS-240PA
240° , up to R16m
at height of 2.5m
(frontal)/R8m(backward)
Adjustable from approx. 5sec to 30min
and Test &
Adjustable from approx. 5Lux to “
and “ ” (learning range: 5Lux - 500Lux)
& Holiday
” (
∞
)
Can be used to control lighting or HVAC devices (voltage free
contact).
Pulse count function to avoid the false triggering problem
caused by environment.
Excepting the provided Lux values, the ambient light level can
be read-in as the Lux value for more flexible application.
Manual override for lighting on 8hrs. is enabled by using an
external rocker switch to control or IR remote control.
Built-in 4 LEDs provide Warning / Watch function, which
enables the detector to guarantee complete surveillance or
warning respectively.
User friendly design of un-falling mounting base and plug-in
terminal block for installation convenience.
OS-360PA
Φ
32m
Φ
14m
Φ
10m
16m
O
360
2.2 Dimension (See FIG.1-A & FIG.1-B & FIG.1-C)
Wall mount: 150 x 90 x 84mm
8
4m
m
7
9
mm
Φ
90mm
80mm
FIG.3
3.1.2.1 The optimal location for installation is at garden, corridor,
staircase, entrance, garage, public lavatory, outdoor
parking area, home and office, etc.
3.1.2.2 Since the detector responds to temperature change,
please avoid the following conditions:
Avoid pointing the detector toward the objects whose surfaces
are highly reflective, such as mirror, glass, etc.
Avoid mounting the detector near heat sources, such as heating
vents, air conditioners, lights, etc.
Avoid aiming the detector toward the objects which may be
swayed in the wind, such as curtain, tall plants, etc.
3.1.2 Helpful tips for installation
OPEN
OPEN
FIG.2-A
FIG.2-B
OS-240PA
OS-240PA /
OS-300PA /
OS-360PA
5
5
0
16m
16m
7
7
Top view
Side view
O
240
FIG.5
FIG.13
-
A
FIG.13
-
B
3.4.1.5
(See FIG.13-A) to shorten the detection range, or
O
turned leftward and rightward max. 90 horizontally
(See FIG.13-B). Please adjust detector head to get the
desired detection field.
O
Detector head can be adjusted downward max.40
FIG.11
FIG.12-A
FIG.12-B
Non-dropping
screw
Bottom cover
Wall
mount
Ceiling
mount
Rubber
gasket
O
90
O
90
O
90
O
40
FIG.8
Anchor
Wood Screw
Φ
4x10mm
2
2
Wood Screw
Φ
4x25.4mm
2
Jump or wire
2
Lens shield
(
OS-240PA
)
3.4.2 Corner / recess mount with mounting bracket
3.4.2.1 There are cable entry knock-outs at back and bottom
sides. Select the proper holes and break it through for
wiring. (See FIG.14-B & FIG.14-C)
3.4.2.2 Break the desired screw knock-outs (See FIG.14-A). Then
fix the mounting bracket onto recess/conner with wood
screws (See FIG.15-A& FIG.15-B), and fix bottom cover
on mounting bracket (See FIG.16). Refer to FIG.5-FIG.7
to connect power cables, then fix the detector head to
the bottom cover and adjust the detector head to be in
the correct position.
FIG.14-A
FIG.14-C
FIG.9-B
1
Corner
mounting
bracket
Pattern
Item
Quantity
Manual
1
Rubber
washer
Screw support
Cable entry
knock-out
Cable entry
knock-out
3.4.1 Wall mount and ceiling mount
3.4.1.1 When installing, the junction box of detector can be stuck
on the bottom cover by inserting the hook into the slot, so
that you don’t need to hold the product on hand, to make
installation conveniently (See FIG.9-A & FIG.9-B & FIG.9-C)
.
3.4.1.2 Please strip off 6-8mm of cables sheathing by tool before
installation.
3.4.1.3 Feed the electric cables through rubber gasket
(see FIG.8) and refer to illustration of FIG.5 - FIG.7 for
correct wiring, then fit the bottom cover on the wall or
ceiling firmly by two screws (See FIG.10).
The unique holiday mode for randomly switching ON / OFF
load is worked as a simple security function to protect your
property.
The IR remote control is available for quick and convenient
setting (for optional purchase).
Accessories for optional purchase
OS-240PA
/
OS-300PA
/
OS-360PA
3.2
.
3
Holiday function
FIG.15-A
Corner installation
µ
FIG.1-B
Wall corner mounting bracket
(Optional purchase)
:
80 74
.
5 28mm
x
x
7
4
.5
m
m
80mm
28mm
5
5
0
16m
7
7
O
300
OS-300PA
Top view
Side view
FIG.4
Less sensitive to movement
directly towards detector
More sensitive to movement
across the detector
3.2.2 Manual override for switching light on for 8 hours
(Lux is independent)
Under Auto mode, the load will turn on automatically when the
movement is detected and the ambient light level is below the
Lux setting value. When no movement is detected and the
delay time has expired, the load will turn off automatically.
3.2.1 Auto mode
3.2 Function
3.3.3 For HVAC control (See FIG.7)
M
Manual
Switch
A1
A2
Supply
Voltage
Fan
Heater
Contactor
Blue
Brown
Red
Red
N
N
N1
L
L
L1
D1
D2
Motion detector
FIG.7
3
and adjust the detector head to be in the right position
(See FIG.12
-
A & FIG.12-B)
.
.4.1.4 Fix the detector head to the bottom cover (See FIG.11)
FIG.10
6-8mm
FIG.14-B
150mm
6
6
mm
111
m
m
Φ
90mm
80mm
Ceiling mount:
Ceiling mount: 166 x 90 x 111mm
FIG.1-C
166mm
1
2
3
5
4
6
7
8
Set the Lux knob to “Holiday ” position, LED will flash quickly
for 10sec, and then keep on for 10sec to indicate detector
entering into Holiday mode. Detector is uncontrolled by Lux and
Time under Holiday mode.
Under Holiday mode, the light will turn on automatically
when the ambient light level is below 50 Lux. Then the light
will randomly turn ON and OFF between 10min to 1hr for the
next 4hrs. When the load is off, LED will flash by turns. When
the load is on, the 4 LEDs will flash simultaneously under this
mode.
Exit Holiday mode: During the Holiday mode, adjust the
Lux knob to other positions beside “Holiday ”, load will
turn off and LED will flash for 5sec to indicate detector exiting
Holiday mode.
1-8 holes are
s
crew
knocku-outs
FIG.9-C
PASSIVE INFRA-RED SENSOR
FOR AUTOMATION CONTROL
OUTDOOR PIR MOTION DETECTOR
for Lighting or HVAC Automation
Control
OS-360PA OS-300PA OS-240PA
Wall mount:
1s.
Load
Staircase timer
N
L
L
D1
D2
N
Motion detector
L
N
OUT
IN
μ
3.3.2 Staircase timer switch controlled by one sensor (Time should
be set to (See FIG.6).
1S.
Blue
Brown
Red
Red
FIG.6
N
L
5
5
0
16m
16m
7
7
Top view
Side view
O
180
Φ
10m
Φ
14m
Φ
32m
Φ
10m
Φ
14m
Φ
32m
Φ
10m
Φ
14m
Φ
32m
Φ
10m
Φ
14m
Φ
32m