Before you start using this product please follow these basic guidelines: 

1.

 

Please carefully read the manual before through before beginning with the installation process! 

2.

 

The EK High Flow and EK-PSC type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber o-ring gaskets.

 

3.

 

The use of corrosion inhibiting coolants is strongly recommended for any liquid cooling system.

 

STEP 1:  PREPARING THE PUMP 

STEP 2: INSTALLING THE X-RES 

Unscrew the four screws that attaches the Laing pump’s original 
factory top and the main pump core housing with motor. Store 
these four screws as well as factory pump top in a safe place. 

Remember to keep the original o-ring gasket! 

 

 

1.

 

Install the EK-DDC X-RES CSQ on to the pump main 

motor housing. 

Make sure you re-use the original 

o-ring gasket! 

Reseat the gasket if needed. 

You can rotate the DDC X-RES CSQ in and use it in any 
direction (90° step turns). 

2.

 

Secure the DDC X-RES CSQ using enclosed M4x30 

DIN7985 

screws with the Allen (hex) key. Do not over 

tighten the screws as excessive force may strip the 
threading. 

 

STEP 3: ATTACHING DDC ADD ON TO EK-UNI HOLDER D5 

STEP 4: ATTACHING FITTINGS 

 

EK-DDC  X-RES  CSQ  series  reservoir  pump  combo  features  3  (three)  G1/4  threaded 

opening on the main body of which 2 (two) are inlets and one is outlet (clearly marked 
with  ‘OUT’).  EKWB  recommends  using  EK-PSC  fittings  with  the  EK-DDC  X-RES  CSQ 

series reservoir pump combo units. To ensure that the tubes are securely attached to 
the barb/fittings, please use hose clamps or an appropriate substitute. 
 

 
 

 
 
 

 
 

 

 

 
 
 

It is mandatory to use the correct INLET and OUTLET ports: 

1.

 

The OUTLET port (pressure port) is clearly marked with label ‘OUT’ engraved 

on the pump top housing. 

2.

 

The  INLET  port(s)  (suction  port)  are  the  two  recessed  ports  with  G1/4 
threading  on the EK-DDC  X-TOP  front face plane.  You may use any of these 

two ports as an INLET port. It is  necessary to use  the enclosed  EK-Extender 
G1/4 underneath the INLET fitting! Please refer to the picture on the right! 

Do 

not forget to close off

 the unused INLET port using EK-Plug G1/4! 

3.

 

Make sure not to use fittings or barbs with G1/4 thread longer than 5mm! All 

EK-PSC

 and 

High Flow

 fittings are compatible! 

 
 

This water pump & EK-DDC TOP combo can be used in vertical mounting configuration 
(position) only!

 

Mounting the pump upside down may result in pump running dry and 

eventually lead to premature failure of the pump! 

IMPORTANT DISCLOSURES: 

VERY  IMPORTANT  NOTICE:  Once  the  installation  is  completed,  it  is  a  recommended  practice  to  test  the  cooling  circuit  for  leaks  prior  to  powering  up  the  computer.  We 
recommend a 24 hour leak test prior to powering up the computer. Do not test the water block using tap water pressure. This will rupture the top of the housing and render the 
block  unusable  (and  will  void  your  warranty).While  all  efforts  have  been  made  to  provide  the  most  comprehensive  tutorial  possible,  EK  Water  Blocks  assumes  no  liability 

expressed or implied for any consequential damage(s) occurring to your equipment as a result of using EK Water Blocks cooling products, either due to errors or omissions on 
our part in the  above instructions, or due to failure or defect in the EK Water Blocks cooling products. 

 
WARRANTY:Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user. During this 

period, products will be repaired or have parts replaced at our discretion provided that: (I) the product is returned to the agent from whom it was   purchased; (II) the product 
has been purchased by an end user and has not used for commercial purposes;  (III) the product has not been misused, handled carelessly, or used in a manner other than in 
accordance  with the instructions provided describing its installation and proper use. This warranty does not confer rights other than those expressly set out above and does not 

cover any claims for consequential loss or damage.  This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer. This warranty is voided 
if the product comes in contact with aggressive UV additives or other improper liquids. 

 
Any other RMA issues can be reported t

[email protected]

 for further analysis. 

REQUIRED TOOLS 

Philips screwdriver 

 

 

Factory original 

pump top 

Pump impeller 

Sealing gasket (OR) 

DDC pump body 

with motor 

EK-DDC X-RES CSQ

 

Original DDC sealing gasket (OR) 

DDC pump body with motor 

Screw M4x30 DIN7985 

EK-UNI Holder DDC ADD ON 

EK-DDC X-RES CSQ 

EK-UNI Holder DDC ADD ON 

Screw M4x4 DIN7984 

Rubber dumper 

EK- UNI Holder D5 

EK-Extender G1/4 

EK-PSC Fitting 

EK-Plug G1/4 