CONNECTING THE PUMP

STEP 1

The EK-DDC 3.2 PWM has two connectors:

1. 4-pin Molex:

 It must be connected directly to your PSU at all 

times as it is used to power the pump.

2. 4-pin PWM fan:

 It can be connected to your motherboard’s CPU_

Fan or designated water pump header. It can also be connected to 
a controller. This cable is used to control and report the rotational 
speed of the pump. If it’s not connected, the pump will run at 
maximum speed (100% PWM).

STEP 1

4-pin molex 

connector

TESTING THE LOOP

To make sure the installation of EK components was successful, we 
recommend you perform a leak test for 24 hours.

When your loop is complete and filled with coolant, connect the 
pump to a PSU outside of your system. Do not connect power to 
any of the other components. Turn on the PSU and let the pump 
run continuously. It is normal for the coolant level to drop during this 
process as air collects in the distribution plate.

Inspect all parts of the loop, and in the eventuality that coolant leaks, 
fix the issue and repeat the testing process. Ensure that all hardware is 
dry before the system is powered on in order to prevent any damage.

4-pin PWM fan 

connector

Summary of Contents for EK-Classic DP Side PC-O11D G1 D-RGB + DDC 3.2 PWM

Page 1: ...USER GUIDE EK Classic DP Side PC O11D G1 D RGB DDC 3 2 PWM DISTRIBUTION PLATE...

Page 2: ...with the installation process The EK Fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber O ring gaskets The use of corrosion inhi...

Page 3: ...LLING THE DISTRIBUTION PLATE ON THE PC 4 RECOMMENDED DISTRIBUTION PLATE CONFIGURATIONS 5 ATTACHING THE FITTINGS 5 CONNECTING THE D RGB LED STRIP 7 CONNECTING THE PUMP 8 TESTING THE LOOP 8 SUPPORT AND...

Page 4: ...THE PC STEP 1 Remove both side panels from the PC case STEP 1 STEP 2 STEP 2 Place the distribution plate in the right position inside the PC case and install it with twelve M4x8 screws from the backsi...

Page 5: ...rked on the diagrams All remaining and unused ports should be closed using the supplied plugs and a 6mm Allen key EK recommends EK Classic and EK Torque series fittings CONFIG 1 Configuration with one...

Page 6: ...G 2 Configuration with two radiators CONFIG 2 FILL DRAIN RADIATOR 1 INLET RADIATOR 1 OUTLET CPU OUTLET CPU INLET GPU OUTLET one must be used GPU INLET one must be used RADIATOR 2 INLET RADIATOR 2 OUTL...

Page 7: ...ensure that the arrow indicated on the connector is plugged into the 5V line as indicated on your motherboard If you put LED Diode to the 12V RGB HEADER you can damage the LEDs Connector is the same o...

Page 8: ...or TESTING THE LOOP To make sure the installation of EK components was successful we recommend you perform a leak test for 24 hours When your loop is complete and filled with coolant connect the pump...

Page 9: ...r assistance please contact http support ekwb com EKWB d o o Pod lipami 18 1218 Komenda Slovenia EU EKWaterBlocks EKWaterBlocks ekwaterblocks ekwaterblocks EKWBofficial SUPPORT AND SERVICE SOCIAL MEDI...

Reviews: