PRODUCT MAINTENANCE
NP-DK50-10-A-4_10-2019-MD
34
10/2019
17.6. Check of safety valve
Turn the screw (2) on the safety valve (1) several
times to the left until the safety valve releases the
air.
Let the safety valve vent for a few seconds.
Turn the screw (2) fully to the right, the valve must
be closed now.
Fig. 12: Check of safety valve
Risk of pressure increase when safety valve is damaged.
Safety valve must not be used to depressurize the air tank. It could damage the
safety valve function. The valve is set to the maximum allowed pressure, it is
tested and marked.
Safety valve setting must not be adjusted.
Risk of injury when compressed air is vented.
Protect your eyesight when checking the safety valve
– wear protective goggles.
17.7. Inlet filter replacement
Pull out the rubber plug (2) by hand.
Remove the dirty inlet filter (1).
Insert a new filter and mount the rubber plug.
Fig. 13: Inlet filter replacement
17.8. Replacement of filter element
Risk of injury during work with pneumatic components under pressure.
Before any of the following operations on the device, disconnect the device from
the mains and decrease pressure in the air tank and pneumatic system to zero.
Remove the tube (1) from the quick coupling.
Loosen the filter bowl (3) using a wrench and dismantle.
Dismantle the filter element (4) by pulling it downwards.
Insert a new filter element.
Summary of Contents for DK50-10 Series
Page 1: ...DK50 10 User manual Benutzerhandbuch N vod na pou itie...
Page 2: ......
Page 4: ...CONTENTS 5 INHALT 41 OBSAH 77...
Page 13: ...PRODUCT DESRIPTION 10 2019 13 NP DK50 10 A 4_10 2019 MD Fig 2 DK50 10Z M Compressor with dryer...
Page 14: ...PRODUCT DESRIPTION NP DK50 10 A 4_10 2019 MD 14 10 2019 Fig 3 Compressor DK50 10S M 8 10bar...
Page 85: ...POPIS V ROBKU 10 2019 85 NP DK50 10 A 4_10 2019 MD Obr 2 DK50 10Z M Kompresor so su i om...
Page 86: ...POPIS V ROBKU NP DK50 10 A 4_10 2019 MD 86 10 2019 Obr 3 Kompresor DK50 10S M 8 10bar...
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......