Safety park vehicles, with a key (16) close the stacker and press the emergency stop switch (2).
Unscrew the 2 screws on the main cover, remove the main outer cover. First unscrew the
6.2. Power Meter
Discharge with 4 LED display to show
6.3. Charge
Optional automatic voltage charger can only be applicable to the mentioned 110V or 220V. Charging
space must ensure good ventilation. After the completion of the charging of the battery, disconnect
the connector from the socket, and put it in the specified storage location.
7. Regular Maintenance
Only qualified and trained personnel should inspect the maintenance of this truck.
Before maintenance, please always remover any products from the fork up and lower the forks to the
lowest position.
For lifting procedures, review the specified instructions according to the fourth chapter lifting
equipment. Before the operation, please safety secure movement of the truck (such as a specified jack,
wedge or wood) under the truck to ensure security of movement.
Please pay attention to the maintenance of the handle bar. There is a gas spring has pressure.
Please use the original spare parts approved and issued by your dealer.
Please consider the leakage of the hydraulic fluid which may cause the machine breakdown and
accident.
Only allow repair technician trained for pressure regulating valve.