background image

 
 
 
 

 

 

 

 
 

Gateway configuration manual  

PROFINET Slave -  

KNX TP 

EK-BN1-TP 

 

 

 

Summary of Contents for EK-BN1-TP

Page 1: ...Gateway configuration manual PROFINET Slave KNX TP EK BN1 TP...

Page 2: ...play and connection elements 6 3 Configuration and commissioning 8 4 Profinet protocol general information 9 4 1 Tecnology 9 4 2 Profinet CBA 9 4 3 Profinet IO 9 4 4 Addressing 9 4 5 Real time RT 10 4...

Page 3: ...ve The informations exchanged over the Profinet network are updated over the KNX network by means of a twisted pair TP communication cable The device manages a two way data stream the Profinet registe...

Page 4: ...alues of the acquired communication objects are stored in a 1440 byte volatile memory buffer KNX image memory This buffer is independent from the Profinet image memory buffer Profinet network Register...

Page 5: ...e Configuration and commissioning of the ekinex gateway must be performed using the application program CGEKBN1TP available for download at www ekinex com The PC where the application program is insta...

Page 6: ...rk connection and device configuration via Ethernet as well as one 1 way microswitches are also present Figure 1 Switching display and connection elements 1 KNX bus line terminal blocks 2 KNX programm...

Page 7: ...linking 0 5 Hz loading configuration Yellow LED 10 KNX communication Blinks when a frame is received Fast blinking no configuration Very slow blinking 0 5 Hz loading configuration Yellow LED 11 Device...

Page 8: ...rt delays CGEKBN1TP application software to properly configure the gateway Knowledge of the ETS automation project with particular attention to communication objects and group addresses passing on the...

Page 9: ...rresponding outputs which are then sent to another controller 4 3 Profinet IO The peripheral interfacing is implemented by Profinet IO protocol Profinet IO defines the whole data exchange between mast...

Page 10: ...e base for Profinet IO data exchange Real time data are treated with a greater priority than TCP IP or UDP IP data this kind of data exchange allows to achieve cycle times inferior to 1ms 4 6 Isochron...

Page 11: ...inet network creation of GSD file to import in master s configuration Firmware and or configuration update The application program consists in multiple modal windows called forms each form must be clo...

Page 12: ...ytes Each support byte can be individually addressed see Position field in KNX Set Access form or you can target a specific support bit in each buffer Bit Mode field in KNX Set Access form As shown in...

Page 13: ...configuration files are stored on the hard drive in XML format Figure 5 Create new configuration form Figure 6 Create new configuration form In order to duplicate an existing project you must find th...

Page 14: ...BN1 TP Revision 1 0 2 Update 10 12 2018 Configuration manual EKINEX S p A All rights reserved Page 14 5 3 Software Options The Software Options form allows you to select a different language for the a...

Page 15: ...ameter identifies the physical address assigned to the KNX device The format requires the use of a dot as a separator beween the 3 fields area line and device address Here are the conventions used for...

Page 16: ...2 Update 10 12 2018 Configuration manual EKINEX S p A All rights reserved Page 16 Parameter name Values Description PROFINET Name of Station Profinet device name Number Byte IN Number of input bytes...

Page 17: ...s as a filter Through this field you can acquire datapoints of all lines over the KNX bus 0 0 0 value or you can select one specific line e g 4 3 0 or a single device identified by a specific physical...

Page 18: ...r the datapoint over the KNX bus If OnChange field is selected OnTimer in selected and Poll Time 0 the gateway will send the commands both cyclically and on change of the data acquired over the Profin...

Page 19: ...Profinet registers configuration By pressing Profinet XML button you can access to the form that creates the GSD XML file which contains the information about the data to be exchanged between the Prof...

Page 20: ...1 way microswitch A see Figure 1 Switching display and connection elements to ON position Power on the device Connect PC and device by means of an Ethernet cable Make sure that the PC s network parame...

Page 21: ...rrectly applied the procedure the text Device found will appear see Figure 12 Update configuration form Press Next button see Figure 12 Update configuration form Select the desired options see Figure...

Page 22: ...run the program using the primary OS When using Windows 7 or later make sure the user has administrator privileges Pay attention to firewall settings Check LAN configuration In case of manual firmware...

Page 23: ...nex KNX defective devices must be returned to the manufacturer at the following address EKINEX S p A Via Novara 37 I 28010 Vaprio d Agogna NO Italy 7 Other information This application manual is aimed...