Cut-out
The sensor coating is highly durable against chemical
substances and mechanical damages, e.g. dust.
The sensor surface is resistant against the following
chemicals:
detergents
(soap,
Armor
All
(plastic
cleaner/preservative),
Formula
409,
etc.),
Food
&
Beverages
(Cola, coffee, juice, etc.),
alcohol
,
oil, grease,
petrol
,
brake fluid,
etc.,
hand lotion
.
Generally speaking, the finger scanner does not require any
maintenance.
The only exception is visible dirt on the sensor.
If this is the case, please clean the sensor area.
Recommendation:
Clean the finger scanner using a wet,
soft and not scratching rag.
Mounting Bracket
Sealing Flanch
(only for outdoor operation)
Mounting Bracket
b)
Before you start with the actual installation, hold on tight the finger scanner, inserts, spacer and
design frame, and the mounting bracket to check how to position the mounting bracket to level
the scanner with the design frame.
c)
Tighten the mounting bracket
(1)
on the gang box
(2)
either in position
A
or position
B.
A
or
B
results from the installed position of the bracket
(3)
.
Position
A
: short distance | Position
B
: large distance (i.e. distance between bezel and mounting bracket)
(4)
. For fine-tuning the final
position, please use one or more inserts.
IP33/43 is realized via spacers and design frames from different the producer of electric switches.
Using the frame supplied by ekey, you can reach IP44
(5)
.
d)
Once you have decided on the final position, place the cable as shown in the drawing above and
tighten the finger scanner
(6)
using 2 screws to the mounting bracket.
e)
Finally, clip the bezel
(7)
onto the finger scanner.
a)
Use a gang box according to DIN49072.
Pay attention to the specified installation
height of either
155 cm
or
100 cm
from
ground level.
The gang box has to stick to the minimum
dimensions as outlined in the drawing above
(DIN49072).
The recommended installation height is
155 cm
from ground level to the lower
edge of the scanner (or higher)!
To safeguard proper operation by the user,
resulting in an acceptable rate of
recognition, pay attention to the specified
installation height!
Alternatively, you can also install the finger
scanner horizontally. The recommended
installation height is
110 cm
then!
Make sure to have enough space on both
sides of the finger scanner to allow proper
operation with all fingers.
Horizontal installation
Installation Height
Installation
1
5
5
c
m
a)
Cut out an area of W
39,5 mm
H
85
mm
D
16 mm
in the door panel or door frame
(1)
.
b)
Use the supplied screws (
2x. 2,9 x 19 / 2x 2,9 x 38
) for mounting the finger scanner
(2)
.
Attention!
Do not tighten screws too much; otherwise the housing might
get damaged! By tightening the screws, the 3 clamps
(3)
will move outwards securing the finger scanner.
c)
Finally, clip the design element
(4)
onto the finger scanner.
For the installation into a solid wall you will require a mounting bracket. Please contact your ekey installer for further details!
Make sure to have enough space on both
sides of the finger scanner to allow proper
operation with all fingers.
The recommended installation height is
155 cm
from ground level to the lower
edge of the scanner (or higher)!
To safeguard proper operation by the user,
resulting in an acceptable rate of
recognition, pay attention to the specified
installation height!
1
5
5
c
m
Installation Height
Installation
You might not be able
to level
the finger scanner and the
design frame with all frames from different producers.
In this case, the ekey FS OM will stick out
on the front side.
The recommended installation height is
135 cm
from ground level to the lower
edge of the scanner (or higher)!
To safeguard proper operation by the user,
resulting in an acceptable rate of
recognition, pay attention to the specified
installation height!
Make sure to have enough space on both
sides of the finger scanner to allow proper
operation with all fingers.
1
3
5
c
m
a)
To mount the ekey FS WM 2.0
(1)
, please use the supplied screws and plastic dowels.
(2)
Mark the drill holes on the wall
using the mounting bracket
(3)
.
b)
Drill two
5 mm
wide holes and place the dowels into them. Afterwards, fasten the mounting bracket using the corresponding screws.
To establish the electrical connection, please refer to the wiring plan.
c)
Finally, clip the ekey FS WM 2.0 into the mounting bracket and fix the scanner tightening the dedicated screw
(4)
.
Installation Height
Wall-mounted (WM)
integra (IN)
Outlet mounted (OM)
Finger mould
Sensor
The sensor must not be touched using a
sharp
object as it could destroy the sensor!!
Cleaning & Maintenance
This installation manual as well ast he information provided on the accompanying DVD is not subject to any revision. The latest valid version of this document is available under
www.ekey.net.
Subject to optical and technical modifications, any liability for misprints excluded!
Installation
for ekey Finger Scanner (FS)
Description
Unit
Value
Power Supply
VAC
8-24
VDC
8-24
Power Input
W
ca. 1
Temperature Range
°C
-25 up to +75
Memory Size
Fingerprints
home: 99
net: 40/200/2000
Security
FAR
1x 10
-6
FRR
1,4x 10
-2
IP class
IP
44
Matching Speed
S
1-4
Life Span
Swipes
ca. 10 Mio
Dimensions
mm
B:
45
H:
81,6
T:
60,3
Technical Data
Spacer and
Design Frame
Insert
Finger Scanner
Bezel
MOUNTING INSTRUCTION
Gang Box
according to
DIN49072 for installation in
walls
Dimension Gang Box
Description
Unit
Value
Power Supply
VAC
8-24
VDC
8-24
Power Input
W
ca. 1
Temperature Range
°C
-25 up to +70
Memory Size
Fingerprints
home: 99
net: 40/200/2000
Security
FAR
1x 10
-7
IP class
FRR
1,4x 10
-2
IP
IP33/44 depending on
frames
Matching Speed
S
1-4
Life Span
Swipes
ca.10 Mio
Dimensions
mm
B:
50,4
H:
50,4
T:
30,1
Technical Data
The LED indicates a dirty sensor by blinking
red
-
green
Bullet point +
LED
Description
Unit
Value
Power Supply
VAC
8-24
VDC
8-24 (max. 30V)
Power Input
W
ca. 1
Temperature Range
°C
-25 up to +70
Memory Size
Fingerprints
home: 99
net: 40/200/2000
Security
FAR
1x 10
-7
FRR
1,4 x 10
-2
IP class
IP
54 (front end)
Matching Speed
S
1-4
Life Span
Swipes
ca. 10 Mio.
Dimensions
mm
W:
43,6
H:
89
D:
17,3
Technical Data
Opening for cable feed (RJ45)
Fixing Screw
Finger Scanner
Screw
Mounting Bracket
Dowels
Cable
Drill Holes
Design Element
Clamps
Finger Scanner
Screw Driver
ID25: Version: 2, 14.03.2012