ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · [email protected] · www.ek.plus
CM 8SH CI-TC
USER MANUAL
2.- Connect the power supply (
) to the module or
connect it to the previous module using the supplied
power cable.
, power supply can also be
used to power a single module.
3.- Connect the input signals to the transmodulator inputs.
Important note: Pay particular attention to the input type and port. Follow the instructions
on the front panel.
4.- Install the
“CM Management”
software on the PC. It can be downloaded from the website
Software / CM Head-ends Section.
5.- To program the module, perform any of the following connections:
5a.- PC
–
FA 524 programming via USB. Connect the FA 524 power supply to a PC using a USB (A) -
USB (B) cable.
5b.- PC
–
FA 524 programming via Ethernet. Connect the power supply and the PC via Ethernet
cable, connect these on the same LAN (the power supply provided with the address 192.168.0.222).
If it is necessary to be connected when not connected to the LAN itself, the
must be enabled beforehand.
programming via USB. Connect the module to the device using the power and data
cable. Connect the PC to the CM PR via USB cable.
6.- Run the PC SW programming.
power supply or the
and
power supply to the PC before running the software so that it is correctly
detected by the PC driver.
Installation of a multi-module head-end:
In the event of wishing to install the module as a further element of a head-end consisting of other CM
series modules it is very important to follow the instructions below.
•
Connect the different modules in series using of the supplied power cable and then the power supply,
which must always be to the left of the head-end.
•
Check the consumption of the modules. In general, up to 5 modules can be connected with an FA 524
power supply. However, it is recommended to check the power consumptions of the modules to be