Ejoin Charger 22kW Manual Download Page 1

ejoin Charger 22kW

ejoin Charger 7kW

ejoin Wallbox 22kW

ejoin Wallbox 7kW

Manual

Copyright © 2019 ejoin. s.r.o. - All rights reserved

1/24

Summary of Contents for Charger 22kW

Page 1: ...ejoin Charger 22kW ejoin Charger 7kW ejoin Wallbox 22kW ejoin Wallbox 7kW Manual Copyright 2019 ejoin s r o All rights reserved 1 24 ...

Page 2: ...tion thereof 0 This symbol indicates critical safety related information when working with hazardous equipment that pose a risk to human health It is essential to read and observe the information thereof Copyright This document and information contained herein are the intellectual property of ejoin s r o hereinafter the Author based in the Slovak Republic and subject to copyright laws The Author r...

Page 3: ...o Hviezdoslavova 1168 018 63 Ladce Slovakia E mail info ejoin eu Internet http www ejoin eu Info Line 421 424 111 111 Current contact information and contact points for other EU countries are available on the Author s website see above 3 24 ...

Page 4: ...any information contained herein is not clear enough or if you have any inquiries please contact us using the contact information given in this document in the Contact section Product Description i This device is a charging station designed to charge on board batteries of AC enabled electric vehicles It is intended for individual use What Do I Need to Know Before Installing the Charging Station Re...

Page 5: ...hen It Is Allowed to Install the Charging Station 0 If you plan to install the charging station in an outdoor environment do not do so during snowy rainy or humid weather Otherwise water may enter the equipment during installation which can have fatal consequences The charging station has to be acclimatized to the outdoor temperature leave it outside for at least 1 5 hours before opening due to co...

Page 6: ...Pedestal Charger 6 24 ...

Page 7: ...ng stations or 5x6 type 5 core conductor with a full core and cross section of 6mm for three phase charging stations or CYKY J 3x10 5x10 type core cross section of 10mm wiring with this cross section are particularly suitable for longer cables If your charging station is not equipped with a circuit breaker your installation must include a suitable breaker element with a rated current of 32A and br...

Page 8: ...rger The list of the mandatory equipment does not include the tools needed to install the pedestal This depends on the user selected means of anchorage and grounding What Consumables Are Needed to Install the Charger i Four pieces of fastening screws with suitable length and diameter recommended type 4x50mm screw for wallbox only needed to attach the charger cabinet to the anchors Four pieces of a...

Page 9: ... all the installation steps have been performed successfully however please note that before the final commencement it is required to obtain an authorization that the system is fit for purpose from an electrical engineer with a valid license Electrical Inspector 9 24 ...

Page 10: ...s with flammable liquids potential sources of fire and the like The charger contains electrostatic discharge sensitive devices ESD It is advisable to install the charger while wearing antistatic clothing and shoes linen cloth leather and avoid rubber soles and synthetic materials polyester nylon etc Avoid unnecessary contact with the printed circuit board of the control system by hand or a tool Be...

Page 11: ...strip the individual wires at their ends accordingly to avoid exposed cores hanging out from the terminal Afterwards connect all the cores to the X1 or X3 terminal according to their colour and tighten the screws firmly Figure 3 6 Disconnect the FA1 circuit breaker by switching its control lever downward connect the FI1 residual current circuit breaker by switching its control lever upward Check t...

Page 12: ... charging station Before that however check the sealing rubber that must be inserted and not twisted in its groove inside the charger s lid whose both end points must slightly overlap and be placed from the bottom of the charger Turn on the power switch If you have done all the steps correctly LED signalling will light up on the charger s lid 12 24 ...

Page 13: ...hicle Charging starts in few seconds which is indicated by an orange colour slowly fading in and out during the charging process This indicates that the vehicle is charging is everything is OK 4 If the colour switches to blue during charging this indicates that the power has been interrupted briefly by the station owner to prevent overloading of the mains Red colour continuous or flashing indicate...

Page 14: ... phase voltage in the terminal block If the electricity meter s display lights up this indicates a presence of the supply voltage in the charging station Before you plug in the MAIN CONNECTOR and AUXILIARY CONNECTOR to the control system and putting the lid on turn off the power supply again Turn it on again once you re assemble the lid on the charging station If the red light is on continuously c...

Page 15: ... a regular mandatory inspection is given in the applicable standards Test Scope Action Interval Residual Current Circuit Breaker Test Test the operation of the residual current circuit breaker using the button on the breaker while its top lid is removed and power supply connected Every 6 Months Charging Cable Visual Test Test the insulation connectors visually for any damage and or large traces of...

Page 16: ...ments Unprofessional installation failure to observe installation instructions and or implementing unauthorized actions on the charging station Failure to observe manufacturer s operating installation requirements instructions and recommendations during the installation or operation of the charging station Unauthorized use or misuse of the charging station Failure to place the charging cable as in...

Page 17: ...n the charging station immediately as instructed by disconnecting it from the power system by switching off the upstream circuit breaker in your switchgear and taking all actions to avoid its accidental start up by anyone around Afterwards contact your vendor or the original manufacturer and arrange further actions Never try to repair the equipment by yourself Product Designation i All ejoin Charg...

Page 18: ...ation resistance between the PP if applied to the terminal and PE conductors is not measured because a small impedance is connected between them of approx 220Ω may be tested by a multimeter Residual Current Protection This protective function is provided by the FI1 residual current circuit breaker of the A type 30mA and B1 residual current monitor 30mA 6mA The components given in the B1 monitor sp...

Page 19: ...inimum Post Installation IP Protection IP54 Mechanical Strength IK10 Dimensions W O Pedestal 380x235x120mm Weight W O Pedestal To Be Added X1 Power Supply Terminal For Conductors of up to 10mm Cross Section Electricity Meter Modbus Communication Interface Terminal X3 Remote Charging Switch For Conductors of 0 22mm 4mm Cross Section Power Cable Gland PG25 Communication I O Cable Gland If Included P...

Page 20: ...A Fixed Value of 32A Current provided by the charger to the vehicle Actual value depends on the vehicle s specifications Charger Settings range from 6 to 32A via service menu if the charging station is equipped with a GPRS module or Wi Fi optional remote settings Charging Station Idle Power Consumption W O Charging Less Than 8W Charging Mode 3 Charging Connector IEC 62196 Type 2 Included Along W t...

Page 21: ...s Taking Readings Meter Display Total Consumption Pulse Output 1 Configurable 2 5Wh Pulse 10 Wh Pulse 100 Wh Pulse 1 kWh Pulse 10 kWh Pulse 100 kWh Pulse Pulse Duration Configurable 60 100 200ms Pulse Output 2 400 Pulses kWh Modbus RS485 0 to 9999999 99 kWh Pulse Output Properties SPST NO Potential Free Contact of 5 27V Working Voltage and 2 27mA Current Power Readings Accuracy Wh Class 1 Pursuant...

Page 22: ... Terminal Working Voltage Current 24V 13mA Single Core Relay Coil Diode Integrated Correct Relay Coil Controls Polarity Required See Wiring Diagram Control Logic 24V Relay Closed Charging Enabled 0V Relay Open Charging Disabled Miscellaneous Properties Operating Temperature 25 to 45ºC Storage Temperature 25 to 60ºC Relative Humidity Max 95 Non Condensing Altitude Max 2000 Meters Above the Mean Sea...

Page 23: ...vironment the charging station shall not be disposed of along with the municipal waste Therefore it is necessary to deliver the charging station to a yard waste collection or waste disposal company after the end of its service life The packaging material of the charging station as well as this Manual have been made of paper or plastic which can be recycled and disposed along with the municipal was...

Page 24: ...i Country of Origin Information The ejoin charging stations are products that have been designed and manufactured in the Slovak Republic EU 24 24 ...