Cleaning, Maintenance and Care
Eisfink Max Maier GmbH & Co. KG
49
The seals of the covers can be removed for cleaning. Ensure that it is mounted correctly with the
seal ends at the bottom.
DANGER
Danger of electric shock. Dangerous electrical voltage.
►
Unplug mains plug before removing the fan device.
Unplug the plug of the radial fan / plasma generator. Then close with the end cap.
Remove the assembly together with the radial fan by pulling it to the front.
Eliminate any traces of grease. Then rub dry.
Clean the soiled
surfaces of the radial fan
with a
hot cloth slightly dampened
with a
mild
detergent diluted in water. After cleaning, rub the surfaces dry with a
soft cloth
.
Install again in the reverse order.
# Notes on inspecting and replacing the active carbon filter
User tip
The period of use of the Eisfink active carbon filter depends on the type of vapour and the
amount of grease. The degree of soiling of the active carbon filter cannot be visually
assessed. The active carbon filter cannot be cleaned.
►
We recommend
replacing
the Eisfink active carbon filter at least
after 500 operating
hours
. Replace the filters early in the case of unwanted odours.
►
Always replace the active carbon filters completely.
►
Dispose of the active carbon filter with respect for the environment, as domestic waste.