Change setpoints for automatic dosing
In the
MAIN
screen press to select the
DOSING
screen, looking like this:
In this screen setpoints for dosing are shown and can be changed. It is also possible to
start/stop a dosing.
Keys/actions:
Select the previous setpoint/parameter.
Select the next setpoint/parameter.
Start entry of the selected setpoint or chooses the marked action.
Clr
Return to the
MAIN
previous screen.
Setting Coarse and Fine limits
The COARSE and FINE setpoints used for automatic dosing must be specified in the
DOSING
screen.
The COARSE limit is used to control the
COARSE
output indicating high speed dosing until the
COARSE setpoint is reached. The FINE limit is used to control the
FINE
output indicating the
desired amount to be dosed. The setpoints are changed by using and to select the de-
sired set
point (“Coarse”
or “Fine”) with the cursor, and then pressing
to request change
of the setpoint.
Start/Stop of dosing
In addition to starting a dosing using the digital
START
input, a dosing can be started (or
stopped if a dosing is already in progress) using the keyboard in the
DOSING
screen.
A dosing is started or stopped by using and to sele
ct the “Action” parameter with the
cursor, and then pressing
to request the indicated action (“START DOSING” or “STOP DOS-
ING”).
Please notice:
Some other dosing parameters (such as registration period and afterflow cor-
rection) are configured in the
DOSING PAR.
screen.