Eiko VOL22-3CP-XXK-U Installation Instructions Manual Download Page 1

INSTALLATION INSTRUCTIONS

VOL22-3C-XXK-U | VOL22-3CP-XXK-U
VOL24-5C-XXK-U | VOL24-5CP-XXK-U 

SAFETY PRECAUTION:

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and 
other hazards read all warnings and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
For the installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed 
electrician   and check your local electrical code.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

WARNING: RISK OF FIRE OR ELECTRICAL SHOCK

Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
Turn off the power when you perform any maintenance.
Verify that supply voltage is correct by comparing it with the luminaire label information.
All wiring connections should be capped with UL approved wire connectors.

CAUTION: RISK OF INJURY

Avoid direct eye exposure to the light source while it is on.
Account for small parts and destroy packing material, as these may be hazardous to children.
Risk of burns.  Disconnect power and allow fixture to cool before changing bulb or handling fixture.

GREEN GROUND SCREW PROVIDED IN PROPER LOCATION.  DO NOT RELOCATE.
MINIMUM 90

˚

C SUPPLY CONDUCTORS.

SPECIFICATIONS AND DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
SUITABLE FOR DRY OR DAMP LOCATION, TYPE IC.

INSTALLATION:

ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!

1.  Bend out mounting tab 90 degrees on 

each corner.

2.  Use side cutters to adjust each tab to 

height of T-grid.

3.  Lay fixture into T-grid.

4.  Bend tabs flush against T-grid in order 

to clear corner for ceiling tile.

5.  Use a #8×1/4” sheet metal screw 

to fasten fixture to T-grid and use a 

hanger wire to tie off appropriately in 

accordance with local building codes 

(screws and hanger wires supplied by 

others).

6.  Ensure that the wiring of the last fixture 

in the row is properly terminated.Then 

make all electrical connections to the 

fixture.  Attach the wiring access cover 

plate.

EiKO Global, LLC • 23220 W. 84th St, Shawnee, KS 66227 • (P) 1-800-852-2217 • (F) 1-800-492-8975 • eiko.com
EiKO Canada • 81 King St, Barrie, Ontario L4N 6B5 • (P) 1-705-721-5189 • (F) 1-705-721-7855 • [email protected]

FIG. 1

FIG. 2

FIG. 3

FIG. 4

FIG. 5

FIG. 6

Black (Line)

White (Neutral)

Green (Grd)

Purple (Dim+)

Gr

ey (Dim-)

Blue (-)

Red (+)

LED DRIVER

Dimming Wire 

to 0-10v IEC 

compliant control

Lead wire to 

LED load

120-277v

WIRING DIAGRAM