Eguana Evolve 0513 ESS Owner'S Manual Download Page 7

 

 

3 System Monitoring 

 

The system can be viewed online at www.mypowermyway.com.  You will receive 
an automated invitation to setup your account after the installer has completed 
the system installation. 
 
From the monitoring system, you will be able to: 

 

Monitor  your  solar,  battery,  and  home  energy 

consumption. 

 

Manually adjust the emergency battery reserve 

capacity. 
 
For  a  complete  tutorial  on  the  monitoring  system, 
login  to  your  account,  and  select 

tutorial 

in  the 

support  widget  at  the  center  of  the  dashboard 
menu.  

 

3.1 Setting the emergency reserve capacity 

 
The default operating mode of the system will be set to 
maximize energy savings while the utility supply is 
operating; either through a time-of-use plan*, or via a 
solar self consumption plan .  While in this operating 
mode, the battery capacity’s default partition will assign 
75% of the battery for daily energy savings, and 25% for 
emergency backup power.  

* where applicable.  

 
In the event of a planned utility outage, or due to an 
extreme weather event forecast, the battery reserve 
capacity can be changed to prioritize the entire battery for 
emergency backup power use.  
 

1.

 

Click on the gear icon at the top-right of the 
Battery Reserve widget. 

2.

 

Click the “Enable Emergency Power Reserve” 
drop-down list, and select the desired duration. 

3.

 

Click on the save button to update the settings. 

 
The battery will return to the default mode after the 
selected day/week duration expires. Manual updates will 
be required if “until disabled” is selected. 
 
 
 

1

 

2

 

3

 

Summary of Contents for Evolve 0513 ESS

Page 1: ...DO 58159 Evolve ESS Owner s Manual...

Page 2: ...Evolve documents please visit our website at www eguanatech com WARNING Read this document in its entirety before using this product Failure to follow instructions or warnings can result in electrica...

Page 3: ...1 OVERVIEW 3 3 SYSTEM MONITORING 4 3 1 SETTING THE EMERGENCY RESERVE CAPACITY 4 4 OPERATION 5 4 1 LED DISPLAY INDICATORS 5 4 2 LED DISPLAY DEFINITIONS 5 5 BACKUP POWER OPERATION 5 5 1 BACKUP POWER DI...

Page 4: ...e installed location In case of fire When safe use a fire extinguisher suitable for use including A B and C dry chemical fire extinguishers or carbon dioxide extinguishers Do not use type D extinguish...

Page 5: ...rical panel Ensure proper electrical grounding in accordance with code requirements CAUTION Both AC and DC voltage sources are terminated inside this equipment Each circuit must be disconnected before...

Page 6: ...onsists of two main components 1 Evolve ESS includes the power control system PCS and the battery 2 Evolve Hub includes equipment which connects the monitoring system to the home s internet connection...

Page 7: ...utility supply is operating either through a time of use plan or via a solar self consumption plan While in this operating mode the battery capacity s default partition will assign 75 of the battery...

Page 8: ...f the loads connected to the system and the availability of the solar PV supply This system is designed to reliably provide power to a refrigerator home lighting home electronics and small appliances...

Page 9: ...hutdown in backup mode See section 5 2 to restart the system Low SOC shutdown initiated while out of service See troubleshooting section 7 service light on in backup mode 5 2 Restarting the battery sy...

Page 10: ...Green LEDs reduce the load by shutting off circuits in the backup electrical panel then press and hold the service button 5 seconds to resume backup power operation If the battery low SOC shutdown mod...

Page 11: ...ake a warranty claim Record of purchase including date of installation installer name and contact details Serial numbers for the EMS and Battery System cabinets PCS Battery EMS gateway UID this is the...

Reviews: