background image

8 Port Nway Fast Ethernet Switch

User's Manual

FDX

10/100M

LINK/ACT

POWER

1

2

3

4

5

6

7

8

DC 7.5V

NORMAL  UPLINK

Summary of Contents for eG8TS

Page 1: ...8 Port Nway Fast Ethernet Switch User s Manual FDX 10 100M LINK ACT POWER 1 2 3 4 5 6 7 8 DC 7 5V NORMAL UPLINK...

Page 2: ...perated in a commercial environment This equipment generates uses and radiates radio frequency energy and if not installed and used in accordance with the user s manual may cause interference in which...

Page 3: ...r DC 7 5V 4 NORMAL UPLINK Switch 5 Uplink Port 5 LED Indicators of 8 Port 10 100Mps Switch 6 LED Definitions 7 Power LED 7 FDX LED 7 10 100M LED 7 LINK ACT LED 7 Chapter 4 8 Installation 8 To connect...

Page 4: ...vironment where traffic on the network and the number of user increase continuously The small compact rigid size was specifically designed for small to medium workgroups The Switch can be installed wh...

Page 5: ...lex 200Mbps bandwidth on each port Broadcast storm control Store Forward switching methods IEEE 802 3x flow control for Full duplex Zero Packet Loss Back pressure flow control for Half duplex Non bloc...

Page 6: ...One User s Manual Magnet optional Note If any of these items is found missing or damaged please contact your local supplier for replacement 3 8 Port Nway Fast Ethernet Switch User s Manual 8 Port Swi...

Page 7: ...her devices The Switch provides 8 10 100Mbps switching ports that could sense the 10 100M speed and negotiate Full Half duplex mode automatically These switching ports allow users connect the Switch t...

Page 8: ...ed forward in UPLINK position it allows users to connect with a Hub or a Switch using straight through twisted pair cable IV Uplink Port Shared with the port 1 for expanding to another Hub or Switch T...

Page 9: ...duplex 8 1 8 Off Half duplex 8 1 8 Flashing Partial collision 8 1 8 occurs 10 100M Green On Port is on the 8 1 8 100M status Off Port is on the 8 1 8 10M status LINK ACT Yellow On 10 100Mbps port 8 1...

Page 10: ...g Collisions occurred and the port is operating at Half duplex mode 10 100M LED On The port is on the 100Mbps status Off The port is on the 10Mbps status LINK ACT LED On The port is ready for 10 100Mb...

Page 11: ...se straight through twisted pair cable Cat 5 to connect the Switch to PCs servers and other network devices The Normal Uplink Switch is on the Normal position Networks can be build as figure shown 8 P...

Page 12: ...tch is on the Uplink position If you connect the Switches on port 1 to port 8 the cable should be changed to crossover cable Normal Uplink Switch is on the Normal position 9 1 2 3 4 Dual Speed Hub Upl...

Page 13: ...IEEE 802 3x 5 Network Transmission Media 10BASE T Cat 3 4 5 UTP STP 100BASE TX Cat 5 UTP STP 6 Network Status Monitoring LEDs Per port LINK ACT 10 100M FDX System POWER 7 Buffer Memory RAM 2Mbits per...

Page 14: ...100M FDX 10 100M FDX LINK ACT LINK ACT POWER RESET UP LINK 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 1 3 5 7 2 4 6 8 9 11 13 15 18 20 22 24 10 12 14 16 17 19 21 23 PC PC PC FTP S...

Page 15: ...DOC UMWS080R001...