Temperature should be within 18ºC~28ºC and the fluctuation range should be within ±1ºC.
When the temperature is <18ºC or >28ºC, add temperature coefficient error 0.1x (specified
accuracy) /°C.
Capacitance
Range
Resolution
Accuracy
Overload Protection
4.000nF
0.001nF
±(4.0%+10)
600Vrms
40.00nF
0.01nF
400.0nF
0.1nF
4.000uF
0.001uF
±(4.0%+5)
40.00uF
0.01uF
400.0uF
0.1uF
4.000mF
0.001mF
±10%
• Measured value = displayed value - open circuit value of the test teads (For capacitance
≤100n F, it is reco mme nded to use “REL” measurement mode.)
• For capacitance range, open circuit allows least significant digit ≤20.
Temperature
Range
Resolution
Accuracy
Overload Protection
-40ºC~40ºC
1ºC
±4ºC
600Vrms
40ºC~500ºC
±(1.5%+5)
500ºC~1000ºC
±(2.0%+5)
-40ºC~104ºC
1ºF
±6ºF
104ºC~932ºC
±(2.0%+6)
932ºC~1832ºC
±(2.5%+4)
NCV
Range
Electric field sensing
sensitiity level
Overload Protection
NCV
EFLo
To sense the wire above 24±6V and identify
whether the mains socket is charged.
EFHI
To sense the wire above 74V±12V, to identify
whether the mains socket is charged, or
to judge the live/neutral wire of the socket
according to the intensity of the sensing.
Test results may be affected by different socket designs or wire insulation thickness.