Product:
Project:
UV BARx1 version 2.2
2201075
Page:
Latest updated:
8 af 12
30.07.2020
www.efsen.dk
Maintenance
1.
Cleaning of UV BARx1
a.
The UV BARx1 must be turned off 2 minutes in order to cool down.
b.
Disconnect UV BARx1 from wall plug before you start cleaning.
c.
Use gloves - do not touch the UV lamp with your hands and fingers.
d.
Clean the UV lamp with Isopropyl Alcohol on a lint-free cloth.
e.
The outside case of UV BARx1 can be cleaned with slightly wet cloths and soap.
2.
Changing the UV lamp
a.
The UV BARx1 must be turned off for 2 minutes for cool down.
b.
Disconnect UV BARx1 from wall plug before changing the UV lamp.
c.
Use gloves - do not touch UV lamps with your hands and fingers
.
d.
Remove the protective screen in the bottom of the UV BARx1 using
a screwdriver.
e.
Release the UV lamp in the end where the plug is by pressing the
red tab and pulling gently this end of the UV lamp towards you.
f.
Then gently pull the UV lamp out of the clamp in the other end to
release the UV lamp completely.
g.
Dispose of used UV lamp (see paragraph 3 below).
h.
When changing the UV lamp, only use EFSEN 60W UVC bulb
p/n 914.8020.