![EFOY Pro 800
Pro 800 Duo
Pro 2400
Pro 2400 Duo Manual Download Page 62](http://html1.mh-extra.com/html/efoy/pro-800-pro-800-duo-pro-2400-pro-2400-duo/pro-800-pro-800-duo-pro-2400-pro-2400-duo_manual_2367504062.webp)
Operation
Page 62
5.5.3
Manual Off
INFO:
To protect the components, the device should not be switched off until it
has been running for at least 30 minutes since it was started. If the device
is switched off before this period has elapsed, it will continue running for
the remainder of the required running time. The message "Shutdown
procedure" is shown on the display. Do not disconnect the fuel cartridge
or battery during the shutdown procedure.
INFO:
The battery protection and automatic antifreeze functions remain active
after the device is switched off.
1.
Press
on the operating panel, or select
"Operating mode" in the main menu. The op-
erating mode selection appears.
2.
Select the "Manual Off" operating mode.
3.
Press
[ok]
to confirm your selection.
4.
Wait until the shutdown procedure has fin-
ished and "Shutdown procedure" is no longer
displayed on the info screen.
The EFOY Pro fuel cell shuts down in a con-
trolled manner when you press
[ok]
. This
may take some time, to ensure that all pro-
tective features are applied.