Installation
Page 23
Connecting the off-heat duct
The off-heat duct supplied enables a controlled discharge of warmed air,
which allows the device to be operated even in confined spaces.
1.
Supply air,
at least
ø
10 cm / 3.95 in
2.
Exhaust air
3.
Exhaust gas
The off-heat of the heat exchanger needs to
be conducted from the installation space to
the outside sideways or downwards in a ø
10 cm / ø
3.95 in duct.
The supply air side must not be guided by a
duct to ensure that the installation space is
well ventilated.
1.
Sink the screws for the off-heat
flange into the holes provided at the
air outlet of the EFOY Pro fuel cell.
2.
Attach the off-heat bow to the off-
heat flange.
Use the off-heat bow to conduct
warm air sideways or downwards. If
you do not need the off-heat bow, you
can connect the off-heat tube directly
to the off-heat flange.