![EFORT ER15-1400 Operation And Maintenance Manual Download Page 64](http://html1.mh-extra.com/html/efort/er15-1400/er15-1400_operation-and-maintenance-manual_2367471064.webp)
Electrical Operation and Maintenance Manual for ER15-1400 Industrial Robot
59
Fig. 4-5 Fuses and Fuse Gears
The following table details the steps to replace fuses and fuse cores.
Table 4-10 Steps to Replace Fuses and Fuse Gears
Number
Steps
1
Disconnect the power supply of the control cabinet;
2
Determine the position of the fuses and fuse cores. FU1 on the left side of
the right side panel of the control cabinet, upper end of the mounting rail,
fuse core inside the fuse base.
3
Replace the fuses and fuse cores of the same specification;
4
Connect the cables, restore the control cabinet and power on.
Mandatory Measures
When replacing the fuse cores, please keep the new ones the same
as the factory specifications, so as to prevent the device from failing
to disconnect normally when there is a short circuit or overcurrent,
which may damage other devices!
4.5.6 Replace the Fan
Fig. 4-6 Fans
The following table details the steps to replace the fan.
Table 4-11 Steps to Replace the Fan
Number
Steps
1
Disconnect the power supply of the control cabinet;
Cooling unit 1
Cooling unit 2