85
Appendix 2 Controller Alarms and Warnings
1.1 Controller Alarms
1.1.1 System Alarms (1-999)
1.1.1.1 Alarm 1
Fault Description: Abnormity in the value of user register that can be kept
Fault Reasons: The read value of user register that can be kept is inconsistent with that of the last time
when it was switched off.
Solutions: If an alarm occurs after the controller is powered on, please keep pressing the red ADV
button on the controller and restart it.
1.1.1.2 Alarm 2
Fault Description: Abnormity in the value of parameter register that can be kept
Fault Reasons: The read value of the parameter register that can be kept is inconsistent with that of the
last time when it was switched off.
Solutions: If an alarm occurs when the controller is powered on, please keep pressing the red ADV
button on the controller and restart it.
1.1.1.3 Alarm 3
Fault Description: Abnormity in system alarm information
Fault Reasons: The system alarm information is inconsistent with that of the last time when it was
switched off.
Solutions: If an alarm occurs when the controller is powered on, please keep pressing the red ADV
button on the controller and restart it.
1.1.1.4 Alarm 10
Fault Description: Abnormity in encoder connection
Fault Reasons: Encoder fault
Solutions: Check the wiring between the encoder and the controller.
1.1.1.5 Alarm 11
Fault Description: Abnormity in following error
Fault Reasons: The difference between the target position and the actual position exceeds the
maximum allowable value.
Summary of Contents for EC2-S
Page 2: ......
Page 4: ......
Page 10: ......
Page 34: ...EFORT INTELLIGENT EQUIPMENT CO LTD 24 15 19 21 front left side panel bottom plate 16 17 20 18...
Page 84: ...EFORT INTELLIGENT EQUIPMENT CO LTD 74...
Page 85: ...Electrical Operation and Maintenance Manual for Control Cabinet of EC2 S Industrial Robot 75...
Page 86: ...EFORT INTELLIGENT EQUIPMENT CO LTD 76...
Page 87: ...Electrical Operation and Maintenance Manual for Control Cabinet of EC2 S Industrial Robot 77...
Page 88: ...EFORT INTELLIGENT EQUIPMENT CO LTD 78...
Page 89: ...Electrical Operation and Maintenance Manual for Control Cabinet of EC2 S Industrial Robot 79...
Page 90: ...EFORT INTELLIGENT EQUIPMENT CO LTD 80...
Page 91: ...Electrical Operation and Maintenance Manual for Control Cabinet of EC2 S Industrial Robot 81...
Page 92: ...EFORT INTELLIGENT EQUIPMENT CO LTD 82...
Page 120: ......