background image

EFKA DA320G5351 

18

 

5  List of Parameters 

 
 
 

5.1 Operator 

Level 

 

Parameter   Designation 

Unit 

Limits 

Preset  for 

Ind.

  

 

 

   

 

max  min 100

 220

  

680

 1000

   

000 

c2  Number of stitches of start backtack 

stitches  254 

 

2  A 

  

forward 

001 

c1  Number of stitches of start backtack 

stitches  254 

 

4  A 

  

backward 

002 

c3  Number of stitches of end backtack 

stitches  254 

 

3  A 

  

backward 

003 

c4  Number of stitches of end backtack 

stitches  254 

 

3  A 

  

forward 

004 

LS  Light barrier compensating stitches 

stitches  254 

 

4  A 

 

  (for long stitches) 

005 

LSF  Number of stitches of the light barrier filter  stitches  254 

 

0  A 

 

  for knitted fabrics 

006 

LSn  Number of light barrier seams 

 

15 

 

1  A 

007 

Stc  Number of stitches for the seam with stitch stitches  254 

10 

10 

 

10 

10  A 

  

counting 

008 

-F-  A parameter from the technician level is assigned to 

 

2  A 

 

  key 9 on the V820 control panel  

 

  1 =  Softstart On/Off 

 

  2 =  Ornamental backtack On/Off 

 

  3 =  High lift for walking foot (only if parameter  

 

      250 or 255 = 11) oprational mode stored  

 

      = On / operational mode not stored = Off 

 

  4 =  Needle cooling On/Off 

 

      (only if parameter 185 = 1) 

 

  5 =  Signals A1 and/or A2 On/Off with slide-in  

 

      strips 1...4 (lefthand arrow = A1,  

 

      righthand arrow = A2) 

009 

LS  Light barrier On/Off 

 

 

0  A 

010 

cLS  Light barrier compensating stitches 

stitches  254 

 

8  A 

 

  (for normal stitch length) 

013 

FA  Thread trimmer On/Off 

 

 

1  A 

014 

FW  Thread wiper On/Off 

 

 

0  A 

015 

StS  Stitch counting On/Off 

 

 

0  A 

023 

AFL  Automatic sewing foot lifting with pedal forward 

 

0  A 

 

  at the seam end, if light barrier or stitch counting is 

  

On 

 

  0 =  Automatic sewing foot Off 

 

  1 =  Automatic sewing foot On 

080 

SAv  Number of start ornamental backtack  

stitches  254 

 

3  A 

  

stitches 

forward 

081 

SAr  Number of start ornamental backtack  

stitches  254 

 

3  A 

  

stitches 

backward 

082 

SEr  Number of end ornamental backtack  

stitches  254 

 

3  A 

  

stitches 

backward 

083 

SEv  Number of end ornamental backtack  

stitches  254 

 

3  A 

  

stitches 

forward 

085 

cFw  Number of stitches for bobbin thread  

stitches  5000 

 

0  A 

 

  monitor  parameter 195 = 1...3 

 
 
 
 

Summary of Contents for DA320G5351

Page 1: ...CONTROL DA320G5351 P E I 0 K L2334a LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No 402311 English FRANKL KIRCHNER EFKA OF AMERICA INC EFKA ELECTRONIC MOTORS GMBH CO KG SINGAPORE PTE LTD...

Page 2: ...ket Connectors 6 3 1 Position of Operating Elements and Displays 6 3 2 Position of the Socket Connectors 7 3 3 Connection Diagram 8 3 4 Connection of a Sewing Light with Transformer 10 4 Timing Diagra...

Page 3: ...n Routine SIR The Fast Installation Routine SIR passes through all parameters necessary for programming the functional sequence and the positions Input parameter 500 Parameter for direction of motor r...

Page 4: ...trimming On Off Decrease of the value indicated in the programming mode S5 key Basic position 1 or 2 Shift key in the programming mode LED1 Indicator for single start backtack LED2 Indicator for doub...

Page 5: ...encoder IPG001 EFKANET Adapter cord 1113229 in case of multiple assignment B41 Socket for motor power supply B80 Socket for actuator B776 Socket for V810 V820 control panel ST2 Socket for solenoid in...

Page 6: ...M5 Output B POS1 Position 1 in7 DB2000 M6 Output A POS2 Position 2 in8 DB3000 M7 LED lefthand thread monitor GEN Generator impulses in9 External light barrier M8 LED backtack suppression recall R N EX...

Page 7: ...barrier module HSM001 Hall sensor module IPG Pulse encoder EB Actuator Pedal step 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 Input A L L H H H L L H H L L H H L L H Input B L H H L L L H H H H L L L L H H Inpu...

Page 8: ...through the cable bushing Area B Connect strands with clamp on the printed circuit board Insert earth lead into plug in device on the housing Close and screw connect the housing Mount the control unit...

Page 9: ...ck speed 113 n7 Trimming speed 116 c2 Start backtack stitches forward 000 c1 Start backtack stitches backward 001 c3 End backtack stitches backward 002 c4 End backtack stitches forward 003 t8 Start ba...

Page 10: ...speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n7 Trimming speed 116 c1 Start backtack stitches backward 001 c3 End backtack stitches backward 002 iFA Activation angle of the thread...

Page 11: ...speed 110 n2 Maximum speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n6 Softstart speed 115 n7 Trimming speed 116 c1 Start backtack stitches backward 001 c3 End backtack stitches backw...

Page 12: ...compensating stitches 004 iFA Activation angle of the thread trimmer 190 FSA Thread tension release switch off delay 191 FSE Thread tension release activation angle 192 tFA Stop time for thread trimm...

Page 13: ...speed 141 2 n4 End backtack speed 113 n7 Trimming speed 116 n12 Automatic speed for stitch counting 118 c3 End backtack stitches backward 002 c4 End backtack stitches forward 003 Stc Stitches of the s...

Page 14: ...imum speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n7 Trimming speed 116 SAv Number of start ornamental backtack stitches forward 080 SAr Number of start ornamental backtack stitches...

Page 15: ...2 Maximum speed 111 n3 Start backtack speed 112 n4 End backtack speed 113 n7 Trimming speed 116 n10 High lift walking speed 117 c2 Start backtack stitches forward 000 c1 Start backtack stitches backwa...

Page 16: ...or walking foot only if parameter 250 or 255 11 oprational mode stored On operational mode not stored Off 4 Needle cooling On Off only if parameter 185 1 5 Signals A1 and or A2 On Off with slide in st...

Page 17: ...c Bobbin thread monitor function is deactivated 1 sec Counter is set to preset value 087 Intermediate backtack with counted stitches 255 0 0 0 0 0 A stitches At setting 0 normal intermediate backtack...

Page 18: ...rS End backtack synchronization speed RPM 3000 200 1700 400 800 500 A 125 n2A Start backtack speed 2 RPM 3000 200 600 600 600 600 A only if parameter 284 ON 126 n2E End backtack speed 2 RPM 3000 200 6...

Page 19: ...ut influence by the pedal machine stop by pressing the pedal to the basic position 2 Limited speed controllable by the pedal up to the set limit parameter 118 3 At fixed speed parameter 118 can be int...

Page 20: ...015 357 A for changing the values turn handwheel or press the key Press the P key twice Settings are completed 172 Sr3 Display on the control Pos 1 to 1A LED 7 lights up Pos 2 to 2A LED 8 lights up 17...

Page 21: ...tor rotation On Off 1 0 0 0 0 0 A 183 t05 Switch off delay of needle cooling after ms 2550 0 2500 2500 2500 2500 A stop 184 chP Minimum number of stitches for high lift stitches 254 0 0 0 0 0 A for wa...

Page 22: ...reduction in the seam and after thread trimming Off 1 Thread tension release and thread tension reduction in the seam during sewing foot lifting On 2 Thread tension release and thread tension reducti...

Page 23: ...ing power for backtacking 1 100 pa 299 1 50 50 50 50 A 1 low holding power 100 high holding power 215 Zrv 0 Last counted forward section in the start 1 0 1 1 1 1 A backtack OFF 1 Last counted forward...

Page 24: ...eter 131 29 Single stitch with stitch length switching 30 Emergency stop 31 38 No function 39 Switch to the next pattern in TEACH IN 40 Switch back to the previous pattern in TEACH IN 41 45 No functio...

Page 25: ...speed limitation 3 Fullness control without speed limitation 4 Single stitch with stitch length switching 5 Lift lower roller 6 Lift lower fabric endstop 7 Thread tension reduction 8 Manual edge trimm...

Page 26: ...ing to setting of parameter 161 14 Handwheel runs in the opposite direction of rotation according to setting of parameter 161 256 bFA Output B A 32 and LED B A 31 after thread 1 0 0 0 0 0 A trimming 0...

Page 27: ...FL 0 Sewing foot lowers when the handwheel 1 0 1 1 1 1 A rotates 1 The functions pedal in pos 1 or automatic sewing foot lift remain effective 267 kFk 0 The edge trimmer remains On independently 1 0 0...

Page 28: ...PGm Selection according to the position sensors 5 0 0 0 0 0 A Setting of socket B18 see chapter Connection Diagram 0 Function as in table on previous page 1 Setting the sensor to position 2 Set posit...

Page 29: ...100 100 A machine shaft calculation formula see instruction manual Attention The transmission ratio should be determined and indicated as precisely as possible 280 SEL Display of the select resistor v...

Page 30: ...810 V820 control panel 0 No function 1 Needle up down 2 Needle up 3 Single stitch basting stitch 4 Full stitch 5 Needle to position 2 6 Output A if parameter 250 0 7 Output B if parameter 255 0 8 Oper...

Page 31: ...9 302 tr1 Starting point for signal A1 3 0 0 0 0 0 A 0 Start at the beginning of the seam 1 Start of the signal triggered by light barrier sensing 2 Start of the signal when the drive stops at the sea...

Page 32: ...stops at the seam end 3 Start from light barrier covered onwards at the beginning of the seam 313 do2 Delay of signal A2 2 0 1 1 1 1 A 0 No delay until signal On 1 Delay over time until signal On 2 De...

Page 33: ...0 0 0 319 309 NA 100 100 NE 10 10 10 10 100 10 100 100 100 100 10 100 LS 0256 B I LD4 100 P 0 FA E NA Start of seam LS Light barrier uncovered or covered at the seam end LS D Light barrier uncovered...

Page 34: ...1 3 3 3 0 3 3 2 1 1 3 3 0 1 0 2 1 0 2 2 0 0 2 0 0 301 Parameter 311 A1 A2 0 0 1 0 0 0 0 0 0 1 1 0 3 0 0 302 312 303 313 10 0 10 0 10 0 0 0 0 10 0 100 0 0 0 0 100 100 100 0 0 0 0 0 0 100 0 100 0 0 0 0...

Page 35: ...E keys are Off 1 P key is On and E key is Off 2 P key is Off and E key is On 3 P and E keys are On 327 EPm Disabling the keys on the control panels 1 0 1 1 1 1 A 0 and keys are Off 1 and keys are On...

Page 36: ...code number or parameter number or to last or to last display InFo F1 input parameter number parameter number Serious Condition On the control On the V810 On the V820 Signification E1 InF E1 InF E1 Th...

Page 37: ...rol panel 1 2 1 2 1 2 1 2 F F F F F2 F2 F2 F2 F2 INSERT DELETE F1 INSERT DELETE F1 INSERT DELETE F1 F1 INSERT DELETE F1 9 10 K L2256e 7 8 6 R R R R R F F F F F2 F2 F2 F1 F1 F1 3 4 5 1 2 Note When chan...

Page 38: ...fka net http www efka net OF AMERICA INC 3715 NORTHCREST ROAD SUITE 10 ATLANTA GEORGIA 30340 PHONE 770 457 7006 TELEFAX 770 458 3899 email efkaus bellsouth net ELECTRONIC MOTORS SINGAPORE PTE LTD 67 A...

Reviews: