- AB600A5015
Parameter List
- 50 -
12 Parameterlist
12.1 Operator Level
The preset values indicated apply to mode 0 (Parameter 290 = 0).
For preset values applicable to other modes see table in chapter 11.1 »Preset Values Depending on Mode«.
Parameters Designation
Unit
Max
Min
Preset
Ind.
002
c3
Number of stitches of cutter at seam begin
Stitches
254
0
2
003
c4
Number of stitches of cutter at seam end
Stitches 254
0
2
004
LS Light barrier compensating stitches
Stitches 254
0
7
005
LSF Number of stitches of the light barrier filter for knitted
fabrics
Stitches 254
0
1
006
LSn Number of light barrier seams
15
1
1
007
Stc Number of stitches for the seam with stitch counting
Stitches 999
0
20
009
LS Light barrier On/Off
1
0
0
013
FA Thread trimmer On/Off
1
0
0
014
Fw Thread wiper On/Off
1
0
0
015
StS Stitch counting On/Off
1
0
0
017
SAb Stop for tape cutting at the seam end On/Off
(Function only when overlock mode is active).
1
0
0
018
UoS 0 =
Sequence “overlock mode with stop”
1 =
Sequence “overlock mode without automatic stop. When the
command “run” is given, the drive runs at the pre-selected
speed. With
pedal in pos. 0
or
light barrier covered
, the
program switches to the next start of a seam without issuing
signals M1/M2.
2 =
As with setting “1”. But with
pedal in pos. 0
signals M1/M2 will
be issued, and the program switches to the next start of a
seam.
3 =
As with setting “1”. But with
pedal -2
signals M1/M2 will be
issued, and the program switches to the next start of a seam.
Intermediate stop and sewing foot lifting with pedal in
pedal -1
is possible.
4 = If the light barrier is covered during the end count for chain
suction, the program switches immediately to the next start of a
seam. If the end count has been completed and the light barrier
remains uncovered, the drive stops.
5 = Tape cutting at the start of the seam with stop
5
0
0