U
SING
THE
E-42
30
Printable Info menu
This section describes how to print pages such as the Test Page and Configuration page from
the Printable Info menu (described on
). The Printable Info menu is accessed through
the Fiery tab (see
Printing the
Configuration page
can be helpful during installation, Setup, and service. After
installing the E-42 (including connecting to the network), and before default settings are
changed in Run Setup, you can obtain a record of the defaults by printing the Configuration
page.
Before you perform any service procedure, you should print the E-42 Configuration page, if
possible, so you are prepared to return the settings to their former configuration, if necessary.
Printing the
Test Page
indicates that the E-42 is functional and that the connection between
the E-42 and the copier/printer is working.
T
O
A
PAGE
FROM
THE
P
RINTABLE
I
NFO
MENU
1 If it is not powered on already, power on the copier/printer and allow it to warm up.
2 If it is not powered on already, power on the E-42 using the power button on the front panel
and allow it to start up completely (approximately three minutes).
3 Make sure that Idle appears on the Fiery Main menu.
If Busy or Printing appears, the E-42 is processing and you must wait until Idle appears.
4 Touch the Fiery tab.
5 Touch Printable Info and then select the page that you want to print.
The E-42 sends the selected page(s) to the copier/printer.
6 If you printed the Test Page, examine the quality of the page.
If the Test Page prints, you know the E-42 is functional and the connection between the E-42
and the copier/printer is working. If the Test Page fails to print, look up printing problems in
the Troubleshooting table on
.
When you examine the Test Page, keep in mind the following:
Restart Fiery
Shut down all E-42 activity in the correct manner and then restart. The following options
are available from the submenu that appears:
Restart Fiery Service:
Resets the server software but does not reboot the entire system.
Network access to the E-42 is temporarily interrupted and all currently processing jobs are
aborted and may be lost.
Restart System:
Shuts down and then reboots the E-42. Network access to the E-42 is
terminated and all currently processing jobs are aborted and may be lost.
Shut Down:
Shuts down all E-42 activity properly.