5-24 5100 ES Model II/III Portable Radio Operating Manual
December 2006
Conventional Mode Features
Press the <
F2
> (Select) key to select a highlighted parameter, and press the
<F1>
key
from one of the main menus to exit keypad programming. Pressing it in the other menus
returns to the previous menu. The Up/Down switch is also used in several menus to scroll
through available selections. Additional information on this parameters is located in the
following sections.
5.15.2 Zone Password
Note
Ensure that the zone password(s) are not lost because they cannot be overridden in the
field. The PC Configure software must be used to display the lost password or program a
new password.
Each zone can be programmed with a password by the PC Configure software to prevent
unauthorized reprogramming of zone by keypad programming. When this password is
programmed, it must be entered before system or channel parameters in that zone can be
changed by keypad programming. The zone password is programmed in the
Zones > Edit
Zone
screen of the PC Configure programmer. This screen is displayed by clicking the
Edit Zone
button. A different password can be programmed for each zone.
When an attempt is made to select a system or channel parameter in a password protected
zone, “Password” is flashed. The password is always eight digits long and is entered using
the same procedure as used for the power-up password described in Section 3.2. After the
password is entered, system and channel parameters for that zone can be reprogrammed
normally.
5.15.3 Zone Change Parameter
The “Chng Zone” menu parameter selects the zone containing the conventional channel to
be reprogrammed. It does not change the zone selected for normal operation.
Press the <
F2
> switch to select the “Zone Chg” parameter and then scroll through the
programmed zones by pressing the Up/Down switch. When the desired zone is displayed,
select it by pressing the <
F2
> switch.
5.15.4 Channel Change Parameter
The “Chng Chan” menu parameter selects the conventional channel to be reprogrammed.
Disabled or SMARTNET/SmartZone/P25 Trunked channels cannot be selected. This does
not change the channel selected for normal operation.
Press the Select switch to select the “Chng Chan” parameter and then scroll through the
programmed channels by pressing the Up/Down switch. When the desired channel is
displayed, select it by pressing <
F2
> switch.
Summary of Contents for 5100 ES II
Page 2: ......
Page 4: ......
Page 6: ......
Page 24: ...1 4 5100 ES Model II III Portable Radio Operating Manual December 2006 Features...
Page 122: ...9 4 5100 ES Model II III Portable Radio Operating Manual December 2006 Password Description...
Page 143: ......