Figure 9 nXR90i performance curve
0.01
0.1
1
10
1000
0
90
10
20
30
50
60
70
80
40
100
100
0
400
800
1200
600
1000
200
1.
2.
nXR90i
3.
4.
Pressure (mbar)
Pumping
speed (
m
3
h
-1
)
Po
w
er
c
on
sump
tion
(W
at
t)
1. Pumping speed with gas ballast
2. Pumping speed without gas ballast
3. Power with gas ballast
4. Power without gas ballast
1. Pumping speed with gas ballast
2. Pumping speed without gas ballast
3. Power with gas ballast
4. Power without gas ballast
Figure 10 nXR120i performance curve
0
20
40
60
80
100
120
140
0.01
0.1
1
10
100
1000
0
400
800
1200
600
1000
200
1.
2.
nXR120i
3.
4.
5.
6.
Pressure (mbar)
Pumping
speed (
m
3
h
-1
)
Po
w
er
c
on
sump
tion
(W
at
t)
1. Pumping speed with gas ballast
2. Pumping speed without gas ballast
3. Power with gas ballast
4. Power without gas ballast
5. Non-continuous speed with gas ballast
6. Non-continuous speed without gas
ballast
1. Pumping speed with gas ballast
2. Pumping speed without gas ballast
3. Power with gas ballast
4. Power without gas ballast
5. Non-continuous speed with gas ballast
6. Non-continuous speed without gas
ballast
3.3 Materials exposed to gases pumped
The materials and the components exposed to the gases in the pump are:
▪
Iron
▪
Aluminium alloy
▪
Steel
▪
Fluoroelastomer (seals)
▪
PFPE lubricant
3.4 Electrical data
If the pump is operating with a supply voltage below the nominal operating range,
example < 200 V in high voltage regions or < 100 V in low voltage regions, the product
will limit the maximum power deliverable to the pump motor. If the application load
exceeds the maximum power available, pump rotational speed will be reduced. Refer to
. At lower rotational speeds pumping performance will be
05/2021 - ©Edwards Limited