Figure 5 nXL200i Dimensions
440 (17.32)
344 (13.54)
150 (5.90)
294 (11.57)
704 (27.72)
243 (9.57)
320 (12.6)
308 (12.13)
3.2 Performance
Table 5 Performance data
Parameter
Units
nXL110i
nXRL200i
Maximum pump speed*
m
3
/hr
110
200
Maximum continuous inlet pressure at
40 °C ambient
mbar
8
Maximum continuous inlet pressure at
30 °C ambient
mbar
15
Maximum continuous exhaust pressure
bar
0.4
Maximum inlet flow to pump down a
100 litre chamber from an atmospheric
pressure
slm
0
NA
Maximum inlet flow to pump down a
75 litre chamber from an atmospheric
pressure
slm
5
0
Maximum inlet flow to pump down a
50 litre chamber from an atmospheric
pressure
slm
25
20
Suck
‑
back protection
By exhaust valve
Leak tightness (static)
mbar l/s
-1
< 1 x 10
-5
* Values for the maximum pumping speed are taken at a sea level. At level higher than
sea level, the pump performance can be affected and the rotational speed can drop
below the nominal value.