Cause
Oil sight glass loose
Remedy
Tighten.
Fault
The expected process vacuum level is not reached
Cause
Too high-pressure drop between process and pump inlet
Remedy
Check the process lines for the correct size and leaks and correct if necessary.
Cause
Clogged air inlet filter element
Remedy
Replace the filter.
Cause
The pump cannot reach stated vacuum
Remedy
Refer to
The pump cannot reach stated vacuum
on page 43.
07/2020 - Page 45
A35104880_B - Fault finding