A750-04-880 Issue F
Page 8
© Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
TECHNICAL DATA
Table 6 - Typical performance data and sealing liquid flow rates: single stage pumps
Pump(s)
Speed *
r min
-1
MP kW
†
Typical performance §
Maximum
sealing
liquid
flow rate
m
3
h
-1
100 mbara
1.0 x 10
4
Pa
200 mbara
2.0 x 10
4
Pa
800 mbara
8.0 x 10
4
Pa
m
3
h
-1
kW
m
3
h
-1
kW
m
3
h
-1
kW
50 Hz operation
SHR 1300S/C/D
1470
15
263
12.3
382
12.3
470
10
2.7
SHR 1400S/C/D
1470
18.5
430
13.9
540
14.5
655
14
2.7
SHR 1750S/C/D
980
30
630
28
1000
28
1145
20
6.5
SHR 1950S/C/D
980
37.5
800
37
1450
37
1550
25
7.0
SHR 11500S/C/D
735
75
1100
64
2000
64
2300
46
12.0
SHR 11850S/C/D
735
90
1300
84
2400
83
2950
66
14.0
SHR 12500S/C/D
585
110
3000
96
4000
96
4300
68
16.0
60 Hz Operation
SHR 1300S/C/D
1740
18.5
306
17
460
17
550
12.6
2.7
SHR 1400S/C/D
1740
22
475
18.5
675
19.5
780
19
2.7
SHR 1750S/C/D
1150
45
700
37
1150
37
1400
28
9.0
SHR 1950S/C/D
1150
55
850
50
1720
50
1900
38
9.5
SHR 11500S/C/D
880
110
1100
97
2250
97
2600
72
14.0
SHR 11850S/C/D
880
160
1500
126
2630
126
3200
96
14.0
SHR 12500S/C/D
585
110
3000
96
4000
96
4300
68
16.0
*
Nominal pump rotational speed.
† Motor power.
§ Performance specifies the suction capacity (m
3
h
-1
) and shaft power (kW) for the