![Edwards A311-01-985 Instruction Manual Download Page 34](http://html1.mh-extra.com/html/edwards/a311-01-985/a311-01-985_instruction-manual_2366072034.webp)
A311-03-880 Issue A
Page 26
© Edwards Limited 2014. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Installation
Figure 9 - Inlet/outlet flange loading limits
A. Side view
B. Plan view
1. Inlet/outlet flange
2. Outlet/inlet flange
F Force
M Moment
R Resultant
X Load orientation
Y Load orientation
Z Load orientation
Note:
HV8000 VF pump shown. The same flange
loading limits apply to all HV8000 pumps.
Maximum force (on both inlet and outlet flanges)
FX
±
100 N
±
22.5 lbf
FY
±
100 N
±
22.5 lbf
FZ
±
200 N
±
45.0 lbf
FR
±
245 N
±
55.1 lbf
Maximum moment (on both inlet and outlet flanges)
MX
±
50 N m
±
36.9 lbf ft
MY
±
50 N m
±
36.9 lbf ft
MZ
±
50 N m
±
36.9 lbf ft
MR
±
87 N m
±
64.2 lbf ft