Figure 74 ASCII settings screenshot
In the HyperTerminal window, type: '?T' and press the ENTER key.
If successful, you should get a reply with the following format:
157,28,19,42,0,72,121,35,0
In this example:
157
indicates the pump controller
28
indicates the GXS pump family
19
indicates the GXS250
42
indicates the GXB2600 booster
0
indicates the GXS screw pump
72
indicates low volts, 7.5 kW DP and 7.5 kW BP
121
indicates a harsh gas module
35
indicates a normal thermal management type
0
indicates a normal exhaust type
Refer to the SIM manual for more information about the various field elements and
what they mean for the system. Any other query and command can be sent by typing
the operation and parameter followed by the ENTER key.
9.14 How to set up the MCM MicroTIM using the PDT
If the MCM MicroTIM is fitted to the system, all the pump configuration settings that are
made using the PDT are automatically stored in the MicroTIM. This means that if a new
system is fitted, for example, while servicing the existing system, there is no need to
configure the new pump settings if the original MicroTIM is used.
The PDT can also be used to configure the channel 2 input and channel 4 output on the
MCM MicroTIM itself. Refer to the MicroTIM instruction manual D37360880 for full
information about MicroTIM installation and setup.
The following menus are used by the PDT to configure the MCM MicroTIM channel 2
input and channel 4 output.
Page 156
M58800880_H - Pump display terminal
Summary of Contents for 9773512584
Page 6: ...This page has been intentionally left blank ...
Page 87: ...Figure 19 GXS160 installation drawing Sheet 4 Page 83 M58800880_H Installation drawings ...
Page 178: ...This page has been intentionally left blank ...
Page 179: ...This page has been intentionally left blank ...
Page 180: ...edwardsvacuum com ...