Technical data
B064-04-880 Issue F
2
Technical data
2.1
Performance
2.2
Mechanical data
2.3
Pump fluid data
Note:
An Edwards Material Safety Data Sheet for AP201 fluid is available on request.
Pumping speed (ISO)
Air
Hydrogen
12500 ls
-1
15000 ls
-1
Ultimate vacuum
less than 1 x 10
-4
mbar, 1 x 10
-2
Pa
Throughput at 1 x 10
-1
mbar (10 Pa)
2.4 x 10
2
mbar.ls
-1
(2.4 x 10
5
Pa.ls
-1
)
Fluid loss at 1 x 10
-1
mbar (10 Pa)
12 g.h
-1
Critical backing pressure
5.3 to 6 mbar (5.3 x 10
2
to 6 x 10
2
Pa)
Maximum system pressure
1.3 bar absolute (1.3 x 10
5
Pa)
Warm-up time to maximum performance
at full-heat input
60 min
Minimum backing-pump displacement for
maximum throughput
290 m
3
h
-1
Recommended backing-pump
Edwards E1M275
Dimensions
Mass
620 kg
Inlet-flange
737 mm diameter with 12 equally spaced
20.6 mm fixing-holes on a 686 mm
PCD (pitch circle diameter)
Outlet-flange
279 mm diameter with 4 equally spaced
16.7 mm fixing-holes on a 235 mm PCD
Recommended fluid type
Fluid charge
Apiezon AP201
55 litres
Fluid type
Flash
point ºC
Auto-ignition
point ºC
Molecular
weight
Apiezon AP201
196
305