background image

Page 12

Double Pane Windows

The GC3200 will specify if the coating is located on Surface 1, Surface 2, 
Surface 3, OR Surface 3 or 4.  If the meter does not specifically identify 
Surface 3, you can move to the other side of the window to confirm the low 
e surface.

Single Pane Windows

The GC3200 will specify if the coating is located on Surface 1 or Surface 2 
of a single piece of glass.
 

Triple Pane Windows

The GC3200 will specify if the coating is located on Surface 1, Surface 2, 
Surface 3, or Surface 3or4.  By moving to the other side of the window, the 
meter can specify Surface 5 and Surface 6.  The GC3200 detects the 
presence of low-E coatings on the middle pane of a triple pane unit.  It will 
either show results of Surface 3, or Surface 3or4.  If there are multiple low-
E coatings, the GC3200 will only identify the nearest coating.

Low-E Detection Capabilities

The electronics that detect the presence of the Low-E coatings are impacted by the surroundings of the meter.  This has been explained 
elsewhere in the manual by showing proper hand placement on the meter and positioning of the glass when testing.  The Low-E detection 
circuitry is affected by conductive materials that are detected by the meter.  Conductive materials could include the metal spacer in the window 
or muntin bars (grid) inside the window itself, just to name a few.  Keeping the meter at least 2 inches away from any metal/conductive material 
when taking measurements will result in the most accurate Low-E measurements.  

One additional note regarding Low E detection.   If your application contains more than one low e coating in the window, the Glass-Chek ELITE 
will only identify the first (nearest) Low E coating that it encounters.  Testing from the opposite side of the window would allow you to identify 
the other Low E coating in the window.  The GC3200 detects the presence and location of low-E coatings on the following applications:

GL

AS

S 1

GL

AS

S 2

AIR SP

ACE 1

AIR SP

ACE 2

GL

AS

S 3

Triple Pane Window

SURF

ACE 1

SURF

ACE 3

SURF

ACE 2

SURF

ACE 4

GL

AS

S 1

GL

AS

S 2

AIR SP

ACE 1

AIR SP

ACE 2

GL

AS

S 3

Triple Pane Window

SURF

ACE 5

SURF

ACE 6

GL

AS

S 1

GL

AS

S 1

GL

AS

S 2

 AIR SP

ACE

SURF

ACE 1

SURF

ACE 1

SURF

ACE 3

SURF

ACE 2

SURF

ACE 2

SURF

ACE 4

Double Pane Window

Single Pane Window

Monolithic

GL

AS

S 1

GL

AS

S 2

 AIR SP

ACE

SURF

ACE 1

SURF

ACE 2

Double Pane Window

Identifying the Type of Low-E: 

In addition to identifying the location of low-E coatings, the GC3200 determines the type of low-E on your window.  The meter will specify it as 
“hard coat”(aka pyrolytic or on-line coating) or “soft coat” (aka sputtered or off-line coating).  If the Low E is soft coat, the meter will also specify 
the number of silver-layers as single, double, or triple, based on the coating’s energy performance.  If you happen to know the manufacturer of 
the glass, in many cases you can identify the exact type of low-E coating used to make the window.  A convenient reference chart is included 
with the GC3200 meter, that lists many of the common Low E coatings used in the USA.  Here are some examples:

     

SOFT COAT (sputtered)

   

Triple Silver

Double Silver

Single Silver

   

-Cardinal 366

-Cardinal 270 & 272

-Cardinal 180

      -Pilkington Energy Advantage

-PPG SolarBan 70

-PPG SolarBan 60

-PPG Sungate 100 & 400

      -PPG Sungate 500

-Guardian CG 62/27

-AFG TIPS, TIR, & TIAC

-Guardian ClimaGuard 75/68

      -AFG Comfort E2

-Guardian ClimaGuard 71/38

HARD COAT (pyrolytic)

Summary of Contents for Glass-Chek ELITE GC3200

Page 1: ...n MENU Options Page 3 Navigating the MENU Unit of Measure Results Screen Speed Page 4 Operating MODES Page 5 Language Selection Back light Settings Stored Data Page 6 Proper Operation BEST Location fo...

Page 2: ...G MENU screen appears Release the ARROW button once that screen appears You can enter the MENU system any time the meter is powered on by pressing and holding one of the ARROW buttons Please note that...

Page 3: ...in fractions If decimal inches are chosen only the air space thickness and overall IG unit thickness will be shown in decimal inches The glass thickness will always be shown in fractions of an inch wh...

Page 4: ...t results If you need to know the air space of the IG change the MODE to NORMAL GLASS NO LAMI and the GC3200 will measure the IG as a regular double pane window including the air space See the applica...

Page 5: ...ff the back light until the measurement results are obtained This helps to extend the life of the battery Stored Data The GC3200 will automatically save the most recent 30 measurements The stored data...

Page 6: ...st windows in free air not resting on a tabletop surface or stacked on other pieces of glass BOTTOM CENTER Above Back of GC3200 meter with the two lenses circled Use clean compressed air to clean the...

Page 7: ...the meter did not detect a low E coating on G1 or G2 Since the GC3200 only detects coatings on the first 2 panes you may be required to test both sides of a triple pane window to verify the presence...

Page 8: ...by showing the results as a combination of G1 L1 G2 When this occurs the meter was not able to cleanly identify the laminate inner layer surfaces Screen 4 below shows an example of how this will appe...

Page 9: ...clear of any Low E coating In this example the clear glass lami 162 or 5 32 On screens 2 and 4 you will see that these two thickness values are denoted by the letter D D1 D2 Because the meter does no...

Page 10: ...itional screen to the rotation of results screens The additional screen is called the ASSUMPTION SCREEN If the user knows that both pieces of glass in the laminated piece that are referenced in the AS...

Page 11: ...to showing a D dimension that groups at least one component into the dimension The D dimension could include a variety of component thickness values in its result For instance the D dimension could i...

Page 12: ...than one low e coating in the window the Glass Chek ELITE will only identify the first nearest Low E coating that it encounters Testing from the opposite side of the window would allow you to identify...

Page 13: ...for low E measurement See the Specifications section on Page 15 of this manual for more details on the GC3200 s maximum thickness ranges Battery and replacement The GC3200 meter is powered by a 9 vol...

Page 14: ...takes varying amounts of time depending on the application Be sure to hold the meter steady against the window until the results are displayed Measurements that will take longer include Laminated Gla...

Page 15: ...ic Glass The GC3200 will display the thickness of single pane monolithic glass up to 2 75 inches or 70mm thick GLASS 1 GLASS 1 SINGLE LITE GLASS GLASS 2 GLASS 2 AIR SPACE 1 AIR SPACE 1 AIR SPACE 2 GLA...

Page 16: ...assumes no liability for the consequential damages of any kind through the use or misuse of the GC3200 product by the purchaser or others No other obligations or liabilities are expressed or implied...

Reviews: